beautypg.com

Quadra-Fire QF130 User Manual

Page 9

background image

9

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

Figure 2.3 Control Module

NG/LP SETTING

STATUS INDICATOR LED

SELECTOR

SWITCH

FLAME HI/LO SWITCH

I. Before Lighting Fireplace

Before operating this fi replace for the fi rst time,

have a

qualifi ed technician:
• Verify all shipping materials have been removed from

inside and/or underneath the fi rebox.

• Review proper placement of logs, ember material and/

or other decorative materials.

• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position

and that the integral barrier is in place.

WARNING! Risk of Fire/Asphyxiation! DO NOT oper-

ate fi replace with fi xed glass assembly removed.
• An Intellifi re Plus

ignition system is standard with this

appliance.

H. Control Module Operation

1. The control module has an ON/OFF/REMOTE selector

switch that must be set. See Figure 2.3.

OFF Position: Appliance will ignore all power inputs and

will not respond to any commands from a wall switch or

remote. The unit should be in the OFF position during

installation, service, battery installation, fuel conversion,

and in the event that the control goes into LOCK-OUT

mode as a result of an error code.

ON Position: Appliance will ignite and run continuously

in the HI fl ame setting, with no adjustment in fl ame

output. This mode of operation is primarily used for

initial installation or power outage operation with battery

backup.

REMOTE Position: Appliance will initiate commands

from an optional wired wall switch and/or the wireless

remote (RC300).

2. If using a wired wall switch with the module in REMOTE

mode, the fl ame output can be adjusted with the HI/LO

selector switch on the module. See Figure 2.3. Note

that the fl ame HI/LO selector switch will become inactive

once an optional remote control (RC200/RC300) is

programmed to the control module. Note that the control

module will always ignite the fi replace on HI and remain

so for the initial 10 seconds of operation. If the HI/LO

is switched to the LO position, the fl ame output will

automatically drop to the lowest setting after the fl ame

has been established for 10 sec. After this 10 second

period, the fl ame can be adjusted from HI to LO with

the switch.

3. The control module has safety feature that automatically

shuts down the fi replace after 9 hours of continuous

operation without receiving a command from the RC300

remote.

4. If you intend to use both an optional wired wall switch

and the RC300 remote control to operate your fi replace,

the wall switch will override any commands given by

the remote.

5.

Module Reset
This module may lock-out under certain conditions.

When this occurs, the appliance will not ignite or

respond to commands. The module will go into lock-out

mode by emitting three audible beeps, then continuously

displaying a RED/GREEN error code at its status

indicator LED.

• Check battery tray. Remove batteries if installed.

Batteries should only be installed for use during power

outages. See Section G.

• Locate the module selector switch. (See Figure 2.3).
• Set the module selector switch to the OFF position.
• Wait fi ve (5) minutes to allow possible accumulated gas

to clear.

• Set the module selector switch to ON or REMOTE

position.

• Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-

ule reset switch more than one time within a fi ve minute

time period. Gas may accumulate in fi rebox. Call a quali-

fi ed service technician.