Quadra-Fire QF130 User Manual
Page 31
31
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11
Log #2 (SRV2227-702): Rest left end of log on the fl at spot of Log 1. See Figure 6 and Figure 8. The left end of the log
should touch the left refractory panel. The right end rests on the burner. Push the right end back, until it touches the edge
of the log support.
Log #3 (SRV2227-701): Mate the notch with the right grate tine as shown in Fig 9. The back of the log should rest on the
log support as shown. Rotate the back end of the log clockwise until it contacts the right refractory panel.
Figure 8. Place Log #2
LOG CONTACTS REFRACTORY
LOG RESTS ON BURNER
LOG CONTACTS
LOG SUPPORT
Figure 9. Log #3
LOG RESTS ON
REFRACTORY SUPPORT
LOG GROOVE
(FOR LOG #6)
NOTCH MATES WITH
RIGHT GRATE TINE
Figure 10. Log #4
Figure 11. Log #4
LOG PIN
MATES
WITH SLOT
LOG GROOVE
(FOR LOG #6)
NOTCH
MATE NOTCH
WITH GRATE BAR
2
3
4
Figure 6. Placement of Log #1
Log #1 (SRV2227-703): Mate the notch located on the bottom of the log, with the left grate tine. See Figure 7. The back
end of log should line up with the left edge of the pilot bracket as shown in Figure 6.
FLAT SPOT FOR LOG #5
NOTCH
FLAT SPOT FOR LOG #2
NOTCH MATES WITH LEFT
GRATE TINE
Figure 7. Location of Notch on Log #1
LOG CORNER ALIGNS
WITH PILOT BRACKET
1