beautypg.com

Specifications – QUAD Vaccume Tube Amplifier Systems User Manual

Page 15

background image

15

1 x 6111 twin triode

‹0.2%
0.02% @ 1W

5Hz–50kHz (+0dB/-0.5dB)

Better than -80dB

15dB

50k ohms

5 x Line level
2 x Buffered tape loops

Model

QC-twentyfour

4 x 6111

‹0.08% (A-weighted)

20Hz–20kHz (+0dB/-0.5dB)

Better than 60dB

47Ω
10Ω

1.3mV (MM)/130uV (MC)
2.6mV (MM)/260uV (MC)
5.2mV (MM)/520uV (MC)

1.0
Selectable MC/MM cartridge
1 x fixed line level
1 x variable line level
15 VA maximum

QC-twentyfour P

Valve Complement

THD @ 1V

RMS

Frequency Response

Hum and Noise

Line Stage Gain

Recommended Min. Load

Inputs

Valve Complement

THD

Frequency Response

Hum and Noise

Input Impedance

Moving magnet

Moving coil

Stage Gain

High sensitivity

Medium sensitivity

Low sensitivity

Nominal output level

(ref 5.2mV, MM, Low)

Inputs

Outputs

Power consumption

specifications

40W

RMS

0.3% @ 40W
0.03% @ 1W

Better than -80dB

10Hz–30kHz(+0dB/-0.5dB)

20 @ 700Hz

180W maximum

4 ohm and 8 ohm

2 x 6SH7 Input
2 x KT88 Output
1 x 5U44G Rectifier

1V

RMS

15W

RMS

0.3% @ 12W

Better than -90dB

10Hz–20kHz(+0.2dB)

11.75 @ 700Hz

90Va maximum

8 ohm

2 x EF86 input
2 x KT66 Output
1 x GZ34 Rectifier

1.4V

RMS

Model

II-forty

II-classic*

Power Output

THD @ 700Hz

Residual hum & noise

Frequency Response

Damping Factor

Power Consumption

Loudspeaker Taps

Valves

Sensitivity

*The Quad II Classic power amplifiers are supplied in matched pairs.