Performing an Emergency Reset and Cartridge Eject

Quantum A-Series Tape Drives User’s Guide

68

Performing an Emergency Reset and Cartridge Eject

If the A-Series LTO-3A tape drive stops communicating with the host

computer, use the following procedure to reset the drive and eject a

cartridge (if necessary).

To perform an emergency reset, hold down the load/unload button

between 5 to 15 seconds, and then release it.

Caution:

When you perform an emergency reset and cartridge

eject, any data in the drive or host buffers will not be

written to the tape and the tape record may not be

correctly terminated with an end-of-data mark. If the end-

of-data mark is not written to the tape, you will not be

able to append any data to that tape unless you overwrite

the existing data on the tape.

IF there is . . .

Then the tape drive firmware . . .

no tape in the drive,

restarts the drive and begins the Power On

Self Test function.

a tape in the drive,

ignores all outstanding SCSI commands,

ejects the tape, restarts the drive, and begins

the Power On Self Test function.

Caution:

When you power down the LTO-3A drive, keep the drive

in the power off condition for at least 10 seconds before re-

applying power.