Power On Self-Test (POST) Troubleshooting

Quantum A-Series Tape Drives User’s Guide

23

Power On Self-Test (POST) Troubleshooting

This section provides troubleshooting information that might be helpful

should the system fail its power on self-test (POST).
See the data cartridge appendices in this document (

Data Cartridges

) for

complete visual inspection instructions for Super DLTtape II data

cartridges.
The Web site

www.dlttape.com

also includes valuable information about

SDLT systems.

POST Operation

3

The A-Series tape drive performs a power on self-test (POST) each time

the tape drive is powered on. POST normally completes in 10 to 15

seconds—when a data cartridge is not in the tape drive— when the unit is

powered on. However, if a data cartridge is in the tape drive when the

unit is powered on, POST duration is longer, depending on how much

tape in the data cartridge may be loaded in the tape drive.
See

Front Panel LEDs and Tape Eject

to help familiarize yourself with the

LEDs on the front panel.
For the SDLT 600A tape drive, Stage 3 in the following table provides the

sequence of operations to expect when power is turned on.

Table 4 LED Lighting Pattern
During Power-On Self-Test
(POST)

Stage

What You Observe

1 (Power

On)

All LEDs illuminate for approximately one second.

2

The LEDs flash on, then off in a progressing pattern from

left to right. Stages 1 and 2 generally complete within

approximately five seconds.

3

The right LEDs remain off, the left LED illuminates

steadily, and the middle LED flashes until POST

completes. This stage typically lasts for 5 to 10 seconds.