Safety Check after Servicing

Examine the area surrounding the repaired location
for damage or deterioration. Observe that screws,
parts and wires have been returned to original posi-
tions. Afterwards, perform the following tests and con-
firm the specified values in order to verify compliance
with safety standards.

1. Clearance Distance

When replacing primary circuit components, confirm
specified clearance distance (d) and (d') between sol-
dered terminals, and between terminals and surround-
ing metallic parts. (See Fig. 1)

Table 1 : Ratings for selected area

Note: This table is unofficial and for reference only.
Be sure to confirm the precise values.

2. Leakage Current Test

Confirm the specified (or lower) leakage current be-
tween B (earth ground, power cord plug prongs) and
externally exposed accessible parts (RF terminals,
antenna terminals, video and audio input and output
terminals, microphone jacks, earphone jacks, etc.) is
lower than or equal to the specified value in the table
below.

Measuring Method : (Power ON)

Insert load Z between B (earth ground, power cord
plug prongs) and exposed accessible parts. Use an
AC voltmeter to measure across both terminals of
load Z. See Fig. 2 and following table.

Table 2 : Leakage current ratings for selected areas

Note: This table is unofficial and for reference only. Be sure to confirm the precise values.

AC Line Voltage

Region

Clearance

Distance (d) (d')

110 to 130 V

USA or

CANADA

≥ 3.2 mm

(0.126 inches)

Chassis or Secondary Conductor

d

d'

Primary Circuit Terminals

Fig. 1

AC Voltmeter
(High Impedance)

Exposed Accessible Part

B

Earth Ground
Power Cord Plug Prongs

Z

1.5k

0.15

µF

Fig. 2

AC Line Voltage

Region

Load Z

Leakage Current (i)

Earth Ground (B) to:

110 to 130 V

USA

0.15µF CAP. & 1.5k

RES. connected in

parallel

i

≤0.5mA rms

Exposed accessible

parts