beautypg.com

Hot cold, Power supply block diagram – Sylvania SRT2232X User Manual

Page 27

background image

L6650BLP

6-9

6-10

Power Supply Block Diagram

4A/125V

F601

4A/125V

LINE
FILTER

L601

AC601

AC CORD

DEGAUSSING
COIL

L691

CN691

PS691

BRIDGE
RECTIFIER

D605 - D608

HOT

COLD

T601

6

4

2

1

13

14

12

11

9

4

3

IC601

ERROR
VOLTAGE DET

Q601

Q602

LIMITER

SWITCHING

Q652

VR661

+B ADJ

Q673

SWITCHING
CONTROL

Q672

Q681

Q696

RL601

+8V

SWITCHING

MAIN CBA

+B

DEF +B

+5V CTRL2

(FROM PIN 18 OF IC333)

P-ON+8V

DG-ON-H
(FROM PIN74 OF IC333)

+8V CTRL

(FROM PIN40 OF IC333)

AL+33V

P-ON+5V

AL+12V

P-ON+12V

Q111

NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.

+B

TP601

10

SWITCHING

Q831

PROTECT-2

(TO PIN 67 OF IC333)

BACK-UP

PROTECT-1

(TO PIN68 OF IC333)

Q682

P-ON+5V

+5V CTRL

(FROM PIN28 OF IC333)

Q683

+5V

SWITCHING

+5V

SWITCHING

+5V

SWITCHING

AL+9V

Q321

+9V

SWITCHING

Q674

SWITCHING
P-ON-ON

P-ON-H
(FROM PIN79 OF IC333)

Q832

SWITCHING
P-ON-ON

SWITCHING
P-ON-ON

HOT CIRCUIT. BE CAREFUL.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE,
REPLACE ONLY WITH SAME TYPE 4 A, 125V FUSE.

CAUTION:

ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE MÊME TYPE DE 4A, 125V.

4A/125V

1

2

FEED
BACK

Q841

(SWITCHING)

SWITCHING
P-ON-ON

Q191

Q851

+9V
REGULATOR

Q961

+5V
REGULATOR

SWITCHING
DG-ON-ON

P-ON+5V

CAUTION !

Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F601) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.