E) Power Line and grounding

E) Power Line and grounding

E) Power Line and grounding

E) Power Line and grounding

E) Power Line and grounding

Fig.12
NOTES:
1) Before connecting the power line, check that

the voltage is correct (see Model Number).

2) For supply connections use 16 AWG or larger

wires rated for at least 75 °C.

3) Use copper conductors only.
4) Do not run input wires with power cables.
5) Polarity does not matter for 24 Vdc wiring.
6) The power supply input is NOT

NOT

NOT

NOT

NOT fuse protected.

Please provide it externally.

Power supply

Type

Current

Voltage

24 V AC/DC

T

500 mA

250 V

100/240 V AC

T

125 mA

250 V

When fuse is damaged, it is advisable to verify
the power supply circuit, so that it is necessary to
send back the instrument to your supplier.

7) Safety requirements for permanently

connected equipment:

- Include a switch or circuit-breaker in the

installation.

- Place the switch in close proximity to the

equipment and within easy reach of the
operator.

- Mark the switch as the disconnecting

device for the equipment.

NOTE: A single switch or circuit-breaker can
drive more than one instrument.

8) When the NEUTRAL line is present, connect it

to terminal 4.

9) To avoid shock and possible instrument

damage, connect power last.

4

5

POWER SUPPLY

100 to 240 Vac

24 Vac/Vdc

N, L2

R (S,T), L1

N, L2

R (S,T), L1

Fig.11

LHL-1-NEUTRO.pmd

19/04/2004, 15.07