Baud, 9600 data, 7par – Omega Vehicle Security PTC900 User Manual
Page 28: Odd addr, 00 abbr, Yes opt, T-dsp, Yes c-dsp, No rtc-d, No rtc-t
28
7-SrL
Serial Communication Parameters
DISPLAY
PARAMETER
FACTORY
SETTING
USER SETTING
bAUd
BAUD RATE
9600
dAtA
DATA BITS
7
PAr
PARITY BIT
Odd
Addr
METER UNIT ADDRESS
00
Abbr
ABBREVIATED PRINTING
NO
REAL-TIME CLOCK PRINT FORMAT
YES
OPt
PRINT OPTIONS
t-dSP
TIMER DISPLAY
YES
C-dSP
CYCLE COUNTER DISPLAY
NO
rtC-d
RTC DATE DISPLAY
NO
rtC-t
RTC TIME DISPLAY
NO
spNt
SETPOINT VALUES
NO
SPNtOF
SETPOINT OFF/ TIME-OUT VALUES
NO
PARAMETER
USER SETTING
FACTORY
SETTING
dSP-t
12-59p
dSP-d
DATE DISPLAY FORMAT
12-31
SyNC
Ch-dSt
sLAVE
N0
OFFSEt
CAL
00
TIME DISPLAY FORMAT
DISPLAY
AUTO TIME CHANGE FOR D.S.T.
SYNCHRONIZATION UNIT TYPE
CALIBRATE REAL-TIME CLOCK
RTC CALIBRATION OFFSET VALUE
9-fCS
Factory Service Parameters
DISPLAY
DISPLAY INTENSITY LEVEL
3
d-LEV
FACTORY
SETTING
USER SETTING
PARAMETER
Shaded areas are model dependent.
Shaded areas are model dependent.
8-rtC
Real-Time Clock Parameters
OUt-n
tOUt-n
SPOF-n
OFF-n
SP-n
ON-n
ASM-n
ACt-n
DISPLAY
NOr
NOr
NOr
NOr
SETPOINT ANNUNCIATOR
POWER-UP STATE
NO
NO
NO
NO
OUTPUT RESET W/DISPLAY RESET
NO
NO
NO
NO
TIMER/COUNTER AUTO RESET
NOr
NOr
NOr
NOr
OUTPUT LOGIC
VALUE
VALUE
VALUE
000100
000100
000100
VALUE
000100
VALUE
VALUE
000100
000100
000100
SETPOINT OFF VALUE (B)*
VALUE
SETPOINT OFF (B)*
TIME-OUT VALUE (B)*
TIME-OUT VALUE (A)
000100
SETPOINT OFF VALUE (A)
VALUE
SETPOINT OFF (A)
LAtCH
LAtCH
LAtCH
VALUE
NO
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
000000
000000
VALUE
VALUE
NONE
SP-4
USER SETTING
NO
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
000000
000000
VALUE
NONE
SP-3
LAtCH
FACTORY
SETTING
USER SETTING
FACTORY
SETTING
VALUE
NO
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
000000
000000
VALUE
VALUE
SETPOINT ON (B)*
NONE
SP-2
SETPOINT ACTION
USER SETTING
NO
TIMER STOP
Mon-Fri
DAILY OFF OCCURRENCE (B)*
Mon-Fri
DAILY OFF OCCURRENCE (A)
Mon-Fri
DAILY ON OCCURRENCE (B)*
Mon-Fri
DAILY ON OCCURRENCE (A)
000000
SETPOINT ON VALUE (B)*
000000
SETPOINT ON VALUE (A)
VALUE
SETPOINT ON (A)
NONE
SETPOINT ASSIGNMENT
SP-1
6-SPt
Setpoint (Alarm) Parameters
FACTORY
SETTING
USER SETTING
FACTORY
SETTING
PARAMETER
PTC901 Application
A big application request has always been for
Real-Time Clocks to display time throughout the
plant. The challenge has been to keep all the
various clock locations synchronized with the
right time. With the new PTC901 Timer/Real-
Time Clock this problem is history. You can install
up to a maximum of 32 units. Simply select one of
the units in the system as the host and the balance
are programmed as slaves. The host will send out
a synchronization pulse every hour to correct the
time on any clock unit wired in the system.
Real-Time Clock Synchronization Network
* See Module 2, Exchanging Parameter Lists, for details on programming this value.