6 module 6 - s, Etpoint, Larm – Omega Vehicle Security PTC900 User Manual
Page 19: Arameters, On-off t-out latch, Parameter menu
19
ª
«
SETPOINT ACTION
This parameter determines the mode for output deactivation as shown below.
Output activation is controlled by the SETPOINT ON parameter setting.
The
and
selections are not available when Setpoint is assigned
to
.
ª
«
SETPOINT SELECT
Select the Setpoint (alarm) output to be programmed. This provides access to
the parameters for that particular Setpoint. The “ ” in the following parameter
displays, reflects the chosen Setpoint number (1 thru 4). After the chosen
Setpoint is programmed, the display returns to
. Select the next
Setpoint to be programmed and continue this sequence for each Setpoint. Select
to exit the module.
and
apply to Quad Setpoint cards only.
ª
«
OUTPUT LOGIC
Normal Output Logic (
) turns the output “on” when activated and “off”
when deactivated. Reverse Output Logic (
) turns the output “off” when
activated and “on” when deactivated.
ª
«
SETPOINT ASSIGNMENT
Select the meter display to which the Setpoint is assigned: Timer (
),
Cycle Counter (
), Real-Time Clock Date display (
) or Real-Time
Clock Time display (
). (The
and
selections only appear if a
Real-Time Clock option card is installed.)
By selecting
, the Setpoint is not assigned to a specific display.
However, the output can still be activated (set) and deactivated (reset) by
various “events”. Such events include the Timer starting or stopping, or another
Setpoint output turning On or Off. The output can also be set and reset through
a User Input function or through serial communications.
This parameter determines when the Setpoint output will activate. Output
activation can occur at a specific Setpoint Value (
) or can be triggered by
various “events”, as shown in the parameter list. Such events include the Timer
starting (
) or stopping (
), or by the action (event) that causes
another Setpoint output to turn On or Off. When programmed for an event, the
Setpoint must not be used as the Setpoint On event for another Setpoint.
Selecting
displays a sub-menu where the Setpoint value is entered. The
Setpoint value is based on the meter display to which the Setpoint is assigned
(
). When assigned to the Timer or Cycle Counter, the Setpoint value is
entered in the same format as the assigned display. When assigned to the Real-
Time Clock Date Display (
), the date value is entered in month.day.year
format (
). When assigned to the Real-Time Clock Time Display (
),
the Setpoint value is always entered in
format (Hours-Minutes with
AM/PM selection). In Setpoint One-shot mode (See Daily On Occurrence), the
One-shot Setpoint is enabled (armed) by scrolling the AM/PM digit until the 2nd
digit decimal point is lit.
SETPOINT OFF
ª
«
ª
«
to
Based on “Setpoint Off” Setting
After “Time-Out Value” Elapses
At Reset (Manual or Automatic)
On-Off Output Mode
Timed Output Mode
Latched Output Mode
OUTPUT DEACTIVATES
DESCRIPTION
ON-OFF
t-OUt
LAtCH
DISPLAY
SETPOINT ON
ª
«
The Setpoint Off parameter only appears when the Setpoint Action (
)
is programmed for On-Off Output mode (
). In this mode, this parameter
determines when the Setpoint output will deactivate. Output deactivation can
occur at a specific Setpoint Off Value (
) or can be triggered by various
“events”, as shown in the parameter list. Such events include the Timer starting
(
) or stopping (
), or by the action (event) that causes another
Setpoint output to turn On or Off. When programmed for an event, the Setpoint
must not be used as the Setpoint Off event for another Setpoint.
Selecting
will display a sub-menu where the Setpoint Off value is
entered. The Setpoint Off value is based on the meter display to which the
Setpoint is assigned (
). When assigned to the Timer or Cycle Counter, the
value is entered in the same format as the assigned display. When assigned to
the Real-Time Clock Date Display (
), the date value is entered in
month.day.year format (
). When assigned to the Real-Time Clock Time
Display (
), the value is always entered in
format (Hours-Minutes
with AM/PM selection).
ª
«
to
6.6 MODULE 6 - S
ETPOINT
(A
LARM
) P
ARAMETERS
(
)
Module 6 is the programming module for the Setpoint (Alarm) Output
Parameters. This programming module can only be accessed if a Setpoint card
is installed. Depending on the card installed, there will be two or four Setpoint
outputs available. The Setpoint Assignment and Setpoint Action parameters
determine the applicable Setpoint features, and dictate which subsequent
parameters will appear for the Setpoint being programmed.
This section of the bulletin replaces the bulletin shipped with the Dual and
Quad Setpoint plug-in cards. Discard the separate bulletin when using Setpoint
plug-in cards with the PTC901 and PTC900.
This module can only be accessed if a Setpoint Card is installed.
= Setpoint Number 1 thru 4
PARAMETER MENU