Timing Diagrams for Predefined Timer Operating Modes
NOTE: Input A is shown as a Sourcing input (active high). If a Sinking input (active low) is used, the logic levels for Input A would be inverted.
Input A
Output 1
T1
T2
T
T1
Input A
Output 1
T
T
Input A
Output 1
T
T
Input A
Output 1
T
T
Input A
Output 1
T
T
Input A
Output 1
T1
T
T2
On-Delay Timing
On-Delay / Interval Timing
Repeat Cycle Timing
Interval Timing (Edge triggered)
Off-Delay Timing
Interval Timing (Level triggered)
The input signal must be wired to both the Input A and
User Input 1 terminals. The Timer Input plug jumper and
the User Input plug jumper must both be set to the
same position (either both SNK or both SRC).
The input signal must be wired to both the Input A and
User Input 1 terminals. The Timer Input plug jumper and
the User Input plug jumper must be set to opposite
positions (one SNK, one SRC) and the Input signal must
be a current sinking type (i.e. pulls input to common).
Parameter Settings for Predefined Timer Operating Modes
MODULE 1 - Timer Input Parameters (
)
MODULE 2 - User Input Parameters (
)
MODULE 6 - Setpoint Parameters (
)
P-UP-1
Lit-1
OrSd-1
AUtO-1
tstP-1
tOUt-1
SPOf-1
OFf-1
SP-1
ON-1
OFF
OFF
OFF
OFF
OFF
OFF
Power-up State
NOr
NOr
NOr
NOr
NOr
NOr
Setpoint Annunciator
NO
NO
NO
NO
NO
NO
Output Reset w/display Reset
NO
NO
NO
0-OFF
NO
NO
Timer/Counter Auto Reset
0-OFF
0-OFF
0-OFF
NO
0-OFF
NO
Timer Stop
T*
N/A
T2*
N/A
N/A
N/A
Time-out Value
N/A
T*
N/A
T2*
T*
N/A
Setpoint Off Value
N/A
VALUE
N/A
VALUE
VALUE
N/A
Setpoint Off
N/A
N/A
T1*
T1*
N/A
T*
Setpoint On Value
t-Strt
t-Strt
VALUE
VALUE
t-Strt
VALUE
Setpoint On
NOr
NOr
NOr
NOr
NOr
NOr
Output Logic
t-OUt
ON-OFF
t-OUt
ON-OFF
ON-OFF
LAtCH
Setpoint Action
t-dSP
t-dSP
t-dSP
t-dSP
t-dSP
t-dSP
Setpoint Assignment
SP-1
SP-1
SP-1
SP-1
SP-1
SP-1
Setpoint Select
INt-E
INt-L
dLYINt
rEPEAt
OF-dLY
ON-dLY
PARAMETER
OUt-1
ACt-1
ASN-1
SPSEL
DISPLAY
EdrS-2
EdrS-2
EdrS-2
LEVrSt
EdrS-2
EdrS-2
Timer Input Operation
rEPEAt
dLYINt
INt-E
INt-L
OF-dLY
ON-dLY
PARAMETER
INP OP
DISPLAY
NO
N/A
OrSt-E
NO
N/A
NO
N/A
NO
rSt-L
NO
N/A
Reset Key
User Input 1
INt-E
INt-L
dLYINt
rEPEAt
OF-dLY
ON-dLY
PARAMETER
rSt
USEr-1
DISPLAY
* Refer to timing diagrams. These parameters are the actual Setpoint On/Off or Time-Out values set by the user for the specific application.
(
SP1-YES
)
NO