Rear view, Terminations – Omega DPF76 User Manual

Page 13

background image

8

LOC

LOCK - This portion of the menu allows you to:
1) lock the program (presets are still accessible)
2) lock all (presets and program are locked).

LC PRG

LOCK PROGRAM - This will lock the program and allow the presets to be changed when the unit is in the
lock mode.

LC ALL

LOCK ALL - This will lock the program and the presets when the unit is in the locked mode. The presets can
be viewed, but not changed.

CODE

LOCK CODE - This message (code) will flash on display for approximately 3 seconds. It will be followed by a
5 digit number (xxxxx). The number you enter here will be the code to lock and unlock the unit.

RELAY

RELAY - This portion of the menu allows you to set your relay operation variables.

A TOT

RELAY A FOR TOTALIZER - When this is selected relay A will activate when the net total has reached
Preset A ("A NET B" Mode ). Relay A will activate when the total of input A reaches preset A ("A SEP B"
Mode).

A RATE

RELAY A FOR RATE - When this is selected relay A will activate when the Rate of input A equals or exceeds
preset A when in "A NET B" or "A SEP B" mode. The relay will drop out when the rate of A falls below preset
A.

A##.#

RELAY A DURATION - This message will appear when "A TOT" is selected. It is the duration which the
relay will remain energized (00.1 to 99.9 sec). If 00.0 is selected, the relay will latch until reset. When the
duration is not at 00.0, the unit will autorecycle.

B TOT

RELAY B FOR TOTALIZER - When this is selected relay B will activate when the net total has reached preset
B ("A NET B" Mode). Relay B will activate when the total of input B has reached preset B ("A SEP B" Mode).

B RATE

RELAY B FOR RATE - When this is selected relay B will activate when the rate of input A equals or exceeds
preset B when in "A NET B" or "A SEP B" mode. The relay will drop out when the rate of A falls below preset
B.

B##.#

RELAY B DURATION - Follow same procedure as A ##.#.

TERMINATIONS

1 2 3 4

REAR VIEW

1 2 3 4 5 6 7 8 9 10 11 12

13 14

Analog Out

Setup Switches

Serial Port

ON

RELA

YS

A

B

13- V+

14- I SINK

ANALOG

OUTPUT

ON

CAL.

0-20mA

COUNT

SET

OFF

RUN

4-20mA

RATE

RUN

1 2 3 4

ON

SWITCH

1- COMMON

2- N.O.(N.C./NPN)

3- COMMON

4- N.O.(N.C./NPN)

5- INPUT A

6- INPUT B

7- 11 - 19 V @ 50mA OUT/+DC IN

8- -DC (GROUND)

9- RESET INPUT

10- 6 - 14 V @ 50mA

11- A.C. INPUT

12- A.C. INPUT