Ntific – Oregon Scientific Oregon Scientic Pro Weather Station WMR86 User Manual
Page 10
10
EN
Accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Memory
Current, Min and Max
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization
Auto or disabled
Clock display
HH:MM:SS
Hour format
12hr AM/PM or 24hr
Calendar
DD/MM or MM/DD
Weekday in 5
languages
(E, D, F, I, S, R)
REMOTE WIND SENSOR UNIT
Dimensions
(L x W x H)
178 x 76 x 214 mm
(7 x 3 x 8.4 inches)
Weight
100 g (0.22 lbs) without battery
Wind speed unit
m/s, kph, mph, knots
Speed accuracy
2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy
16 positions
Transmission of
wind speed signal
Approx. every 56 seconds
Memory
Max wind speed
Battery
2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
Dimensions
(L x W x H)
92 x 60 x 20 mm
(3.6 x 2.4 x 0.79 in)
Weight
62 g (2.22oz) without battery
Humidity range
5% to 95%
Humidity accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Temp. unit
°C / °F
Temperature
outdoor range
-30°C to 60°C (-22°F to 140°F)
Temperature
accuracy
-20°C to 0°C:
+/- 2.0°C (+/- 4.0°F)
0°C to 40°C:
+/- 1.0°C (+/- 2.0°F)
40°C to 50°C:
+/- 2.0°C (+/- 4.0°F)
50°C to 60°C:
+/- 3.0°C (+/- 6.0°F)
RF frequency
433MHz
Range
Up to 100 meters (328 feet)
with no obstructions
Transmission
Approx. every 102 seconds
Channel no.
3
Batteries
2 x UM-4 (AAA) 1.5V
REMOTE RAIN GAUGE
Dimensions
(L x W x H)
114 x 114 x 145 mm
(4.5 x 4.5 x 5.7 inches)
Weight
241 g (0.54 lbs) without battery
Rainfall unit
Mm and in
Range
0 mm – 9999 mm
Accuracy
< 15 mm: +/- 1 mm
15 mm to 9999 mm: +/- 7%
Memory
Past 24hrs, hourly from last
memory reset
Battery
2 x UM-3 (AA) 1.5V
PRECAUTIONS
• Do not subject the unit to excessive force, shock,
dust, temperature or humidity.
• Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
• Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
• Do not clean the unit with abrasive or corrosive materials.
• Do not tamper with the unit’s internal components.
This invalidates the warranty.
• Only use fresh batteries. Do not mix new and old
batteries.
• Images shown in this manual may differ from the
actual display.
• When disposing of this product, ensure it is collected
separately for special treatment and not as household
waste.
• Placement of this product on certain types of wood
may result in damage to its finish for which Oregon
Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.
• The contents of this manual may not be reproduced
without the permission of the manufacturer.
• Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
• Please note that some units are equipped with a
battery safety strip. Remove the strip from the battery
compartment before first use.
NOTE The technical specifications for this product and
the contents of the user manual are subject to change
without notice.
NOTE Features and accessories will not be available
in all countries. For more information, please contact
your local retailer.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn
more about Oregon Scientific products. If you're in the US
and would like to contact our Customer Care department
directly, please visit: https://us.oregonscientific.com/
service/support.asp
For international inquiries, please visit: http://
us.oregonscientific.com/about/international.asp