Opticon

OPR 3001

Specifications Manual



9

6. Optical

Specifications

6.1. Laser Scanning Specification

Parameter Specification Unit

Light-emitting Element

Red laser diode

-

Emission Wavelength

650 ±10 (25° C)

nm

Light Output

1.0 or less

mW

Scanning Method

Bi-directional scanning

-

Scanning Speed

100 ±20

scans/s

Scan angle: 54 ±5

°

Scan Angle

Effective scan angle: 44 (Min)

°

6.2. Laser Scanning Standard

6.2.1.

Laser Scanning Tilt

Laser scanning tilt is the vertical difference between both ends of a laser scan
line. Measure it in the middle of the laser scan line.

• Up to 1.2 degrees angle in vertical direction from the scan origin (mirror

motor).

• Up to 3.1 mm at 150 mm from the scan origin.

6.2.2.

Scanning Curvature

The maximum difference between the laser scan line and the line between both
ends of the laser scan line. Measure it in the middle of the laser scan line.

• Up to 1.27 degrees angle in vertical direction from the scan origin (mirror

motor).

• Up to 3.3 mm at 150 mm from the scan origin.

Figure 2: Laser scanning tilt and curvature