Oki MSM80C154S User Manual
Page 19
![background image](/manuals/205154/19/background.png)
277
MSM80C154S/83C154S
¡ Semiconductor
Capture mode is set when TCLK + RCLK = "0" and CP/
RL2 = "1".
16-bit auto reload mode is set when TCLK + RCLK = "0" and CP/
RL2 = "0".
CP/
RL2 is ignored when TCLK + RCLK = "1".
NAME
ADDRESS
MSB
LSB
7
6
5
4
3
2
1
0
BIT LOCATION
FLAG
FUNCTION
T2CON
0C8H
TF2
EXF2
RCLK
TCLK
EXEN2
TR2
C/
T2
CP/
RL2
T2CON.0
CP/
RL2
T2CON.1
C/
T2
T2CON.2
TR2
T2CON.3
EXEN2
T2CON.4
TCLK
T2CON.5
RCLK
Timer/counter 2 external flag.
This bit is set to "1" when the T2EX timer/counter 2 external control signal level
is changed from "1" to "0" while EXEN2 = "1".
This flag serves as the timer interrupt 2 request signal. If an interrupt is
generated, EXF2 must be reset to "0" by software.
T2CON.6
EXF2
Timer/counter 2 carry flag.
This bit is set to "1" by a carry signal when timer/counter 2 is in 16-bit auto
reload mode or in capture mode.
This flag serves as the timer interrupt 2 request signal. If an interrupt is
generated, TF2 must be reset to "0" by software.
T2CON.7
TF2
Timer/counter 2 count clock designation control bit.
The internal clocks (XTAL1•2 ÷ 12, XTAL1•2 ÷ 2) are used when this bit is "0",
and the external clock applied to the T2 pin is passed to timer/counter 2 when
the bit is "1".
Timer/counter 2 counting start and stop control bit.
Timer/counter 2 commences counting when this bit is "1" and stops counting
when "0".
T2EX timer/counter 2 external control signal control bit.
Input of the T2EX signal is disabled when this bit is "0", and enabled when "1".
Serial port transmit circuit drive clock control bit.
Timer/counter 2 is switched to baud rate generator mode when this bit is "1",
and the timer/counter 2 carry signal becomes the serial port transmit clock.
Note, however, that the serial ports can only use the timer/counter 2 carry signal
in serial port modes 1 and 3.
Serial port receive circuit drive clock control bit.
Timer/counter 2 is switched to baud rate generator mode when this bit is "1",
and the timer/counter 2 carry signal becomes the serial port transmit clock.
Note, however, that the serial ports can only use the timer/counter 2 carry signal
in serial port modes 1 and 3.
Timer 2 control register (T2CON)