Specifications – Omega 3200ST User Manual
Page 19

M-4271/0707, pg. 19 of 26
E.
Specifications
Series
FMA 3200
FMA 3400
FMA 3200ST
FMA 3400ST
Accuracy
(including linearity)
±1.5% of
Full Scale*
±1.5% of
Full Scale*
Second and
third gases
±3.0% F.S.*
±1.5% of
Full Scale*
±1.5% of
Full Scale*
Second and
third gases
±3.0% F.S.*
Repeatability ±0.25%
Full
Scale*
Pressure Rating
150 psig (10.3 bar)
500 psig (34.5 bar)
Pressure Sensitivity
±0.02% Full Scale* per psi (per 69 mbar)
Temperature Rating
Operating Range: 5 to 55ºC
Recommended Range (for best performance) : 10 to 40ºC
Storage Range: 0 to 70ºC
Temperature
Sensitivity
±0.15% F.S.* or less per ºC
Valve Normally
Closed
Positive Shut-off up to 60psig (4 bar)
Body Leak Integrity
1x10
-7
sccs of He
Wetted Materials
Aluminum
304 Stainless Steel
316 Stainless Steel
303 Stainless Steel
304 Stainless Steel
316 Stainless Steel
Epoxy
O-Ring Material
Viton
®
Fitting Material
Choose from acetal, brass, or stainless steel
Recommended
Filtration
20 microns or less
Optional inline filters available
Compatible gases
Clean, dry gases compatible with wetted materials
Output Signal
0-5VDC, Impedance greater than 2.5 KΩ
External Set-point
Signal
0-5VDC, Integrated 2MΩ load
Internal Set-point
Signal
N/A Front
Panel
Adjustment
N/A Front
Panel
Adjustment
Warm-Up Time
Less than 5 minutes
Integrated Display
N/A
3½ digit
N/A
3½ digit
Typical Power
Consumption
Standard: 12 VDC @ 250 mA (12.5-15 VDC)
“E” Suffix: 24 VDC @ 130 mA (22-25 VDC)
Peak Power
Consumption
Standard: 12 VDC @ 400 mA (12.5-15 VDC)
“E” Suffix: 24 VDC @ 260 mA (22-25 VDC)
Electrical
Connections
Integrated 36” (92 mm) cable, terminated with:
Standard: 6-pin Mini-DIN male (PS/2 Style)
D1 Option: 9-pin D-Sub male
D2 Option: 15-pin D-Sub male
Certifications CE
Approved
89/336/EEC (EN 55011 & EN 50082-1)
73/23/EEC Low Voltage Directive
*Specifications from 10-100% of rated flow. Linearity is best fit straight line. All calibrations