d) Connections For The 9 Pin D Sub Connector


Using a suitable mating connector the pins of the integrated connector

should be wired as follows:

Connecting To The Integrated 9 Pin Connector

PIN 3 should be connected to the Positive of the power source.

PIN 4 should be connected to the Negative ( Ground ) of the power

source.

PIN 2 provides the signal output and should be connected to the positive
terminal of the display, data acquisition system or voltmeter.

PIN 8 is the signal negative (ground) and should be connected to the

negative (Ground) terminal of the display, data acquisition system or

voltmeter.


Pin 6 is the input signal and should be connected to the positive terminal

of the voltage source. The (0-5VDC) voltage control signal should be
supplied from a low impedance source.


Pin 7 is the input signal negative (ground) and should be connected to

the negative (Ground) terminal of the voltage source.

Pins 1, 5, and 9 are not used.


Caution: Avoid high voltage static discharges to the input signal

connection. Do not short the input/output signal pins or allow

them to contact the power connections at any time. DAMAGE
WILL RESULT!