4. Environmental

Specifications

4.1. Operating Temperature and Humidity

Temperature: 0 to 40° C

Humidity: 20 to 85%

4.2. Storage Temperature and Humidity

Temperature: -20 to +60° C

Humidity: 20 to 90%

4.3. Ambient Light Immunity

Decoding performance is guaranteed when the range of illumination on a barcode
surface is between zero and the following values:

Incandescent light

3,000 lx

Fluorescent light

3,000 lx

Sunlight 50,000

lx

Figure 2: Ambient Light

Immunity

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

PCS: 0.9

Resolution: 0.25

mm

Symbology:

8-digit Code 39

Quiet Zone:

10 mm

N/W Ratio:

1:2.5

Direct light or specular reflection light from a source should be prevented from entering