Communication failures -4, Communication failures, Error 06 – micropositioner location unknown – Oce North America LIGHTJET 500XL User Manual
Page 20: Error 07 – media guide stuck at home, Error 10 – outfeed timeout fault
LightJet 500XL Maintenance Guide
×
see copyright, disclosure, use and duplication information on pg ii
48058-A
3-4
Error 06 – Micropositioner Location Unknown
Possible
Cause:
Micropositioner has lost servo.
Recovery
Method:
Select Media/Cut and Unload. If problem persists, contact Océ.
Error 07 – Media Guide Stuck at Home
Possible
Causes:
A) Media guides are stuck in their parked position.
B) Mechanical component failure.
Recovery
Methods:
A) Select Media/Cut and Unload. Inspect media guides. Clear physical
obstruction if present.
B) Contact Océ.
Error 10 – Outfeed Timeout Fault
Possible
Cause:
The bottom-of-drum sensor did not sense any media within 30 seconds.
Recovery
Method:
Select Set Up/Motor Control/All Motors Reverse. Retract 150 inches of media.
If error persists, contact Océ.
Communication Failures
Problems that prevent proper communication between the LightJet
®
500XL and the host
computer can cause total loss of communication, prevent certain functions, or corrupt the data
used to generate the image. The LightJet
®
500XL cannot detect:
§ Whether the host computer is unable to generate the proper commands.
§ Some cases of data corruption.
§ When a SCSI cable is bad or disconnected.
§ When the wrong SCSI ID has been selected.
Notes:
1
The LightJet 500XL can detect some, but not all, types of data corruption.
2
The LightJet 500XL is shipped from the factory with the SCSI ID set to 6 (binary 110).