PSIM-AC
PSIM-DC
PSIM-5V
7.0:
Applications (continued)
Application 1: Basic Small Network Connection.
• Power supplied to network from PC via network card, no PSIM used.
• Modules connected using standard communication cables.
Volt drop total in mV
=
cable 1 + module (3 off) + cable 2 + module (3 off)
=
(15.2 x 6) + 0.04(6+5+4+3+2+1) + (15.2 x 3) + 0.04(3+2+1)
=
138 mV
Then approximate voltage at end of network =
nominal supply voltage - calculated volt drop
= 5.1 - 0.138
= 4.96
V
LDN-PS
19
M-3340/1206