Baud rates and divisors for the ‘div1’ mode – Omega Vehicle Security OMG-COMM232-PCI User Manual
Page 9
Card Setup
Omega Engineering COMM+232.PCI
Page 5
To select the maximum data rate (460.8K bps) place the jumper in the divide by 1
(silk-screen DIV1) position.
DIV1
DIV2
DIV4
Figure 3 - Clocking Mode 'Divide By 1’
Baud Rates and Divisors for the ‘DIV1’ mode
The following table shows some common data rates and the rates you should
choose if using the adapter in the ‘DIV1’ mode.
For this Data Rate
Choose this Data Rate
1200 bps
300 bps
2400 bps
600 bps
4800 bps
1200 bps
9600 bps
2400 bps
19.2K bps
4800 bps
57.6 K bps
14.4K bps
115.2 K bps
28.8K bps
230.4K bps
57.6 K bps
460.8K bps
115.2 K bps
If your communications package allows the use of Baud rate divisors, choose the
appropriate divisor from the following table:
For this Data Rate
Choose this Divisor
1200 bps
384
2400 bps
192
4800 bps
96
9600 bps
48
19.2K bps
24
38.4K bps
12
57.6K bps
8
115.2K bps
4
230.4K bps
2
460.8K bps
1