This water heater incorporates a combustion shut off device that shuts the operation of the water heater

down if undesirable combustion conditions occur, such as the presence of flammable vapors or blockage of

the combustion air inlet openings. Please contact a qualified Service Technician if this occurs.

Problem

Possible Causes

What To Do

Condensation

This usually happens when

This is normal. After the water in the tank warms

a new water heater is

up, the condensation will disappear. If, however, the

filled for the first time.

condition persists, examine the piping and fittings

for possible leaks.

Moisture from the products

This is normal and will disappear in time. Excessive

of combustion condensing

condensation can cause main burner outage.

on the tank surface.

An undersized water

Use a water heater size that meets the requirements

heater will cause

of your needs.

condensation.

Yellow flame

Scale on top of the burner.

Contact a qualified service technician to remove scale.

or soot

Flue or Combustion air inlet

Remove obstruction or debris from flue or

openings are restricted.

combustion air inlet openings on water heater jacket.

Not enough combustion or

Proper operation of the water heater requires air for

ventilation air supplied to

combustion and ventilation. See the Combustion and

the water heater location.

Ventilation Air information in the “Installing The

Water Heater” section of this manual.

Unable to light

Air in gas line.

Contact a qualified service technician to purge the air

the main burner

from the gas line.

Gas Cock Knob not

Contact a qualified service technician to correctly position

correctly positioned.

the gas cock knob.

Blocked Exhaust

Contact a qualified service technician to evaluate vent

pipe for blockage.

Pressure Switch

Make sure the pressure switch hose is not "kinked".

Wire Connection not fully

Contact a qualified service technician to confirm wire

secured.

connections.

Combustion Shut-off Device

Combustion shut-off device should be inspected by a

tripped,

qualified service technician.

Gas Control Problem

Contact a qualified service technician.

Main burner does not

Gas Controls (Thermostat’s)

The gas control (thermostat) should be replaced by a

stay lit

single use gas shut-off device qualified service technician.

has opened.

Combustion Shutoff Device

The combustion shutoff device should be inspected

Tripped.

by a qualified service technician.

CAUTION: For your safety DO NOT attempt repair of gas piping, gas control (thermostat), burners, vent connectors or other safety