Installing the water heater.

All joints in the vent piping must be

properly sealed and the following

materials are recommended:
PVC materials should use ASTM D2564

grade cement.
CPVC materials should use ASTM F493

grade cement.
ABS materials should use ASTM D2235

grade cement.
Cleaner-Primer and Medium Body

Solvent Cement:

Cut pipe end square, remove jagged

edges and burrs. Chamfer end of pipe,

then clean fitting socket and pipe joint

area of all dirt, grease or moisture.

After checking pipe and socket for

proper fit, wipe socket and pipe with

cleaner-primer. Apply a liberal coat of

primer to inside surface of socket and

outside of pipe. Do not allow primer to

dry before applying cement.

Apply a thin coat of cement evenly in

the socket. quickly apply a heavy coat

of cement to the pipe end and insert

pipe into fitting with a slight twisting

motion until it bottoms out.

NOTICE: Cement must be fluid; if not,

recoat.

Hold the pipe fitting for 30 seconds to

prevent the tapered socket from pushing

the pipe out of the fitting.

Wipe all excess cement from the joint

with a rag. Allow 15 minutes before

handling. Cure time will vary according

to fit, temperature and humidity.

NOTICE: Stir the solvent cement

frequently while using. Use a natural

bristle brush or the dauber supplied

with the can. The proper brush size is

one inch.
NOTICE: This unit is equipped with a

Flammable Vapor Sensor. Do not apply

power until enough time has passed to

allow the vapors from the primer and

cement to dissipate.

Cementing Joints

WARNING: DANGER

OF FIRE OR BODILY

INJURY - Solvent cements

and primers are highly

flammable. Provide

adequate ventilation and do

not assemble near heat

source or open flame. Do not

smoke. Avoid skin or eye

contact. Observe all cautions

and warnings on material

containers.

CAUTION:

For proper installation:
DO NOT use solvent cement

that has become curdled,

lumpy or thickened.
DO NOT thin solvent

cement. Observe shelf

precautions printed on the

containers.
For applications below 32°F

use only low temperature

type solvent cement.
Appropriate solvent and

cleaner must be used for the

type of vent pipe used (PVC,

CPVC or ABS).

NOTICE: All pipe, fittings, solvent cement, primers and procedures must conform to American

National Standards Institute and American Society for Testing and Materials (ANSI/ASTM) standards.