Asme digital/millivolt atmospheric, Gas pool heaters – Raypak CR-206A User Manual
Page 2

Catalog No.: 6000.38B
Effective: 7-1-08
Replaces: 5-1-08
ASME Digital/Millivolt Atmospheric
Gas Pool Heaters
Model
Notes:
1. Model number suffix indicates pilot type (E = digital, M = millivolt) and fuel type (P = propane, N = natural gas). Example: Model number
CR-406A-EN indicates a unit with digital (IID) ignition using natural gas.
2. Ratings are for natural gas and elevations up to 2,000 feet above sea level. Reduce input 4% for each 1,000 feet above sea level when
installed at over 2,000 feet elevation.
Dimensions (in.)
Shipping Weights (lbs)
Heater
Model
BTUH
Input
(000)
Cabinet
Width
(A)
Flue
Dia.
(B)
Indoor
Drafthood
(C)
(J)
Gas
Conn.
Water
Conn.
Heater with
Stackless
Top
Indoor
Drafthood
CR-206A
199.5
20
6
61-5/8
11-3/4
3/4
2
197
12
CR-266A
266.0
23
7
62
11
3/4
2
216
15
CR-336A
332.5
26
8
63
10-5/8
3/4
2
233
17
CR-406A
399.0
29
9
64-1/2
12-1/8
3/4
2
247
20
Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (800) 872-9725 www.raypak.com