Specification – Rinnai 16e User Manual
Page 35

35
SPECIFICATION
 
 
 
Model………………………………………………..….......………………………..Infinity 16e 
 
Installation…………………………………………...…….…...……. External location only 
 
Fuel…………………………………………………..….…..…………...Natural Gas or LPG *  
 
Control………………………………………………….…….………...……….…..Modulating 
 
Input……………………………………………………..……….……………....5.1 to 34.7 kW 
 
Exhaust type………………………………………..……..Forced Draught Direct Exhaust 
 
Ignition……………………………………………………………….…………...…..Electronic 
 
Burner……………………………………………………...……….…………...Stainless steel 
 
Weight…………………………………………………...……….….…………..…..………15kg 
 
Water flow rate ………………………………………..………….…….…...2.4** to 16L/min 
 
Minimum operating water pressure…………………..……….…..………..……….0.8 Bar 
 
 
Connections 
 
Gas…………………………………………………………...….………………….…….3/4BSP 
 
Water Inlet………………………………………….………...…………………….……1/2BSP 
 
Water outlet…………………………………….………...………………………….…..1/2BSP 
 
Electrical Supply…………………………….…………..……………….230V AC 50Hz 1ph 
  
* Separate models available for Natural gas or LPG fuel. 
** Minimum flow rate based on temperature setpoint and inlet conditions. 
 
Rinnai are continually updating and improving products and reserve the right to 
alter model specifications without prior notice. 
 
 