beautypg.com

Roberts Gorden UHA SERIES 200 User Manual

Page 42

background image

COMBAT

®

UHA U

NIT

H

EATER

I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

36

14.6 Ignition Control

The control mounts to the electrical plate. Pull out
ignition cable and wiring from board, noting their
positions.
Release the four mounting standoffs.
Refit in reverse. Ensure correct location of ignition
cable and all other wiring.

14.7 Axial Fan/Guard/Motor Assembly

The axial fan unit for the heater is supplied
completely assembled and balanced.

14.7.1 Fan Removal

Remove the screws

and washers.

Remove the mounting hardware.

and Replacement

Description

Part Number

Qty.

Axial Fan UHA[S] 150 - 175

90710416

1

Axial Fan UHA[S] 200 - 250

90710417

1

Axial Fan UHA[S] 300 - 400

90710416

2

14.7.2 To Replace the Fan Assembly

To replace the fan assembly, reverse the procedure
shown above.

• Check that the fan blades are free to rotate

before turning on the power to the fan.

• Strictly comply with the color code of the fan

wires to ensure correct operation. See Page 16,
Section 9.3
w
iring diagram.

• Use only genuine ROBERTS GORDON

®

replacement parts.

14.8 Limit Switches

14.8.1 Removal and Replacement

1. Remove the electrical connections to the

switch.

2. Unscrew the two screws securing the

switch.

3. Fit a new switch with two screws.

See Page 38, Section 15.3.

4. Reconnect the electrical connections and test

operation.