Important warning, Register description, Encoder hardware id code – RoboteQ Dual Channel Digital Motor Controller AX2550 User Manual
Page 150: Switch status, Speed or distance 1 or 2

150
AX1500 Motor Controller User’s Manual
Version 1.9b. June 1, 2007
Important Warning
Do not alter any other area locations, as this may cause program execution failure
inside the encoder module.
Register Description
Encoder Hardware ID code
Address:
*84
Returns a 4-bit number identifying the encoder module hardware version and the status of
two on-board jumpers. For Roboteq use only.
Switch Status
Address:
*85
Returns a 4 bit number (4 least significant bits of the byte), each representing the state of
one of the limit switches when installed. The ?W command described at “Read Encoder
Limit Switch Status” on page 147 is a preferred method for reading this information.
Speed or Distance 1 or 2
Address:
*86 - Channel 1
*87 - Channel 2
*98
Destination Register 1 MSB (bits 31 to 24)
4 bytes
Full
*99
Destination Register 1 (bits 23 to 16)
*9A
Destination Register 1 (bits 15 to 8)
*9B
Destination Register 1 LSB (bits 7 to 0)
*9C
Distance 1 (when Position Mode enabled)
1 byte
Full
*8D
Distance 2 (when Position Mode enabled)
1 byte
Full
*86
Speed 1
1 byte
Full
*87
Speed 2
1 byte
Full
*A2
Time Base for speed computation of Encoder 1. Multiply
this number by 256us to obtain the actual Time Base period.
1 byte
Full
*A3
Time Base for speed computation of Encoder 2. Multiply
this number by 256us to obtain the actual Time Base period.
1 byte
Full
*A4
Encoder threshold level (see “Voltage Levels, Thresholds
and Limit Switches” on page 72
1 byte
Full
*A5
Distance divider
1 byte
Full
*A6
Mode Selection
1 byte
Limited
TABLE 28. Encoder Registers
Address
Parameter Description
Size
Access