Install the switch, Attach expansion modules (optional) – Rockwell Tools STRATIX 8000 ETHERNET 1783-MS10T User Manual
Page 29

Publication 1783-UM002C-EN-P - April 2009
29
Chapter 2
Install the Switch
Perform these procedures to install the switch.
Attach Expansion Modules (optional)
The switch can operate as a standalone device with two uplink ports and either 
four or eight Fast Ethernet ports, or you can increase the number of Fast 
Ethernet ports by 8 or 16 by connecting the expansion modules.
Expansion modules are supplied separately.
ATTENTION
If you connect or disconnect the communication cable with 
power applied to this module or any device on the network, an 
electrical arc can occur. This could cause an explosion in 
hazardous location installations.
Be sure that power is removed or the area is nonhazardous 
before proceeding.
ATTENTION
If you connect or disconnect wiring while the field-side power 
is on, an electrical arc can occur. This could cause an explosion 
in hazardous location installations. Be sure that power is 
removed or the area is nonhazardous before proceeding.
ATTENTION
To comply with the CE Low Voltage Directive (LVD), this 
equipment must be powered from a source compliant with the 
safety extra low voltage (SELV) or protected extra low voltage 
(PELV).
To comply with UL restrictions, this equipment must be 
powered from a source compliant with Class 2 or Limited 
Voltage/Current.
IMPORTANT
If you are adding expansion modules, attach the expansion 
modules to the switch before mounting the switch.