Regency H300 User Manual
Wood stoves, H300 cast freestanding woodstove, Minimum clearance to combustible materials
Model
H300
Optimum Effi ciency
74%
Emissions (grams/hr) EPA Certifi ed
4.1 grams/hr
Maximum BTU*
45,500 BTU
Maximum Log Size
18”
Firebox Size
1.71 cu. ft.
Flue Size
6”
Burn Time (typical)*
up to 8 hrs.
* Length of burn time and BTU Range depends on type of wood, climate conditions and
installation.
97
June 2007 Hampton Product Specifi cations Book
Wood Stoves
W
ood Sto
v
es
H300 Wood Stove
Residential Installation “C” Vent (Single Wall)
Unit
(with heat Shield)
From Unit
From Corner
From Vent
centerline
A
B
C
D
E
F
H300
17”
15”
13”
30”
15”
19”
Minimum Clearance To Combustible
Materials
Please read the section below carefully as clearances depend on whether
the airmate or the rear heat defl ector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side
wall or to a corner, and from the rear heat shield to a back wall.
Minimum clearance with side load door in use is 18” (457mm) to side
wall or refer to dimension (A) if the side load door is not used.
26"
(660mm)
6-1/4"
(158mm)
27” (686mm)
16-1/2” (420mm)
15” (381mm)
16-1/8” (406mm)
24” (610mm)
7-1/8”
(178mm)
30-1/4”
(762mm)
27-1/4”
(692mm)
29-3/4”
(737mm)
27” (686mm)
25-1/2” (648mm)
14-7/8”
(378mm)
6”
(152mm)
6”
(152mm)
1-1/4”
(32mm)
Cast Side Shelf
(Optional)
Residential Close Clearance
(To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required
from the stove collar to the ceiling level.
Unit
(with heat Shield)
From Unit
From Corner
From Vent
centerline
A
B
C
D
E
F
H300
15”
10”
9”
28”
10”
15”