Ver y impor t ant set -up instr uctions – Rheem HE80-130LP User Manual
Page 23
23
INT
AKE
EXHA
UST
HO
T
COLD
24"
MIN.
10' - 0" MIN.
MAINT
AIN
12"
MIN.
(18"
MIN.
F
OR
CANAD
A)
CLEARANCE
A
BO
VE
HIGHEST
ANTICIP
ATED SNO
W LEVEL.
MAXIMUM OF 24" ABO
V
E R
O
OF
3" PVC
3" ABS
MIN.
84"
REQ'D
FLOOR MOUNTED
PIPE SUPPOR
T
FIGURE 3 -
VER
TICAL R
O
OF
VENTING
FR
ONT VIEW
3" PVC
3" ABS
MIN.
84"
REQ'D
FIGURE 1 - SIDE
VENTING
SIDE VIEW
FLOOR MOUNTED
PIPE SUPPOR
T
12" MIN.
8" MIN.
3" ABS
MIN.
84"
REQ'D
FIGURE 2 - SIDE
VENTING
SIDE VIEW
1" MIN.
3" CONCENTRIC
VENT KIT
INT
AKE
EXHA
UST
INT
AKE
3" PVC
EXHA
U
ST
FLOOR MOUNTED
PIPE SUPPOR
T
3" PVC
HO
T
COLD
MAINT
A
IN 12" MIN.
(18" MIN.
FOR CANAD
A)
CLEARANCE ABO
V
E HIGHEST
ANTICIP
ATED SNO
W
LEVEL.
MAXIMUM OF 24" ABO
V
E R
O
OF
INT
AKE
EXHA
UST
3" ABS
MIN.
84"
REQ'D
FIGURE 4
VER
T
ICAL R
O
OF
VENTING
W/ CONCENTRIC
VENT KIT
VER
Y IMPOR
T
ANT SET
-UP INSTR
UCTIONS!
USING A COMB
USTION ANAL
YZER,
THE FOLLO
WING RA
TINGS
WILL BE
VER
Y HELPFUL IN SETTING UP
FOR NA
TURAL GAS - CO2 READING SHOULD BE BETWEEN 9 1/2% & 10 1/2%
O2 READING SHOULD BE BETWEEN 3 1/2% & 4 1/2 %
CO READING SHOULD BE UNDER 10 PPM
FOR PR
OP
ANE GAS - CO2 READING SHOULD BE BETWEEN 10 1/2% & 11 1/2%
O2 READING SHOULD BE BETWEEN 3 1/2% & 4 1/2 %
CO READING SHOULD BE UNDER 10 PPM