Ignition lockout, Eco switch open, Eco led flashing – Rheem HE80-130LP User Manual

Page 19

background image

19

POSSIBLE CAUSE

1. Burner ground wire broken

or corroded.

2. Connectors unplugged.
3. Flame probe faulty.
4. Gas shut off.
5. Clogged gas valve.
6. Faulty gas valve.
7. Defective control.
8. Burner improperly adjusted.
9. Dirty burner.
10. Improper line connection.

11. Insufficient flame current.

REMEDY

1. Check wire and connection

at burner.

2. Check connectors.
3. Replace flame probe.
4. Turn on gas supply
5. Replace gas valve.
6. Replace gas valve.
7. Replace control.
8. Adjust burner.
9. Clean burner.
10. Verify green LED on the-
control board is illuminated
when power is applied.
11. Montior flame current.
See note below.

IGNITION LOCKOUT

Gas Valve LED Flashing

NOTE:
The flame current (flame rectification) is monitored by pressing
the blue button to the left of the LEDs during the heat cycle or
when the gas valve LED is illuminated. The 3-segment LED
display will show the actual flame curent. The expected flame
current draw is 4.0 to 5.1 micro-amps.

This condition results from a failure to establish burner ignition
after three successive trials. In such cases:
First - Investigate the possible cause and remedy any

observations.

Second - Momentarily press the red button on the display panel

to reset the lockout condition.

Third - Confirm the proper appliance operation.

POSSIBLE CAUSE

1. Temperature probe is
unplugged.
2. Temperature probe wiring
damaged.
3. Water in tank is too hot.
ECO is tripped.

4. Low water cutoff device is
tripped.

REMEDY

1. Check connectors.
2. Repair wiring.
3. Normal condition when
water temperature exceeds
safety limit. Alow tank to cool
or admit cold water into tank.
Manually reset the control.
Determine cause for overtemp
condition.
4. Make sure tank is full of
water.

ECO SWITCH OPEN

ECO LED Flashing

LINE

K1

COMB
BLOWER

K5

IGNITER
ELEMENT

24

VAC

ECO/VENT

SWITCH

SWITCH

PRESSURE

GAS

VALVE

RLY 1

GAS

VALVE

RLY 2

GAS

VALVE

CONTROL

HEALTH

WATER

TEMPERATURE

K1

K5
K3

K4

K4

K3

CONTROL

ELECTRONICS

LINE

K1

COMB
BLOWER

K5

IGNITER
ELEMENT

24

VAC

ECO/VENT

SWITCH

SWITCH

PRESSURE

GAS

VALVE

RLY 1

GAS

VALVE

RLY 2

GAS

VALVE

CONTROL

HEALTH

WATER

TEMPERATURE

K1

K5
K3

K4

K4

K3

CONTROL

ELECTRONICS