Table C-3: R7184 Troubleshooting

continued from previous page

Procedure Status

Corrective

Action

Burner locks out.

Go to step 10.

9. Check cad cell sighting

for view of flame.

· Disconnect line

voltage power and
open line switch.

· Unplug cad cell and

clean cad cell face
with soft cloth. Check
sighting for clear view
of flame. Replace cad
cell in socket.

· Reconnect line

voltage power and
close line switch.

· Start burner.

Burner keeps running. System is OK.

Indicator light is on.

Remount control onto burner housing. Go to step 6.

10. Check cad cell.

· Disconnect line

voltage power and
open line switch.

· Remove existing cad

cell and replace with
new cad cell.

· Disconnect all wires

from thermostat
terminals to ensure
that there is no call
for heat.

· Reconnect line

voltage power and
close line switch.

· Expose new cad cell

to bright light such as
a flashlight.

Indicator light is off.

Go to step 11.

Continued on next page.