Installation, Exterior vent terminal locations – Regency Ultimate U39-LP1 User Manual
Page 9

Regency
®
U39 ULTIMATE Direct Vent Freestanding Gas Stove
9
EXTERIOR VENT TERMINAL LOCATIONS
A
=
Clearance above grade, veranda, porch, deck, or balcony *(min.
12"/30cm)
B=
Clearance to window or door that may be opened *(12"/30cm)
C=
Clearance to permanently closed window *(min. 12"/30cm)
D=
V
ertical clearance to ventilated soffi
t located above the terminal within a
horizontal distance of (24"/60cm) from the centerline of the terminal (min.
18"/46cm) check with local code.
E=
Clearance to unventilated soffi
t
(min.
12"/30cm)
F=
Clearance to outside corner: with
AstroCap
T
e
rmination Cap (min. 6"/15cm),
with Dura-V
ent termination cap (min. 12"/30cm)
G= Clearance
to
inside
corner:
with
AstroCap
T
e
rmination Cap (min. 6"/15cm),
with Dura-V
ent termination cap (min. 12"/30cm)
H=
Not to be installed above a meter/regulator assembly within (3'/90cm)
horizontally from the centerline of the regulator
.
J=
Clearance to service regulator vent outlet *(min. 36"/90cm)
K=
Clearance to non-mechanical air supply inlet to building or the combustion
air inlet to any other appliance *(12"/30cm)
L=
Clearance to a mechanical air supply inlet *(min. 72"/1.8m)
M=
**Clearance above paved sidewalk or a paved driveway located on public
property *(min. 84"/2.1m)
N=
Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)***
Note: *
As specifi
ed in CGA
B149 Installation Code. Note: Local codes or regulations may require dif
ferent clearances.
**A
vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings a
nd serves both dwellings.
INSTALLATION