beautypg.com

Maintenance, Removing valve – Regency Ultimate U39-LP1 User Manual

Page 39

background image

Regency

®

U39 ULTIMATE Direct Vent Freestanding Gas Stove

39

REMOVING VALVE

2) Undo the six screws holding the control

panel in place.

3) Disconnect all wires from the back of the

panel and then remove panel. You should
lay the panel on a soft cloth so it doesn't get
marked up. See diagram below.

6) Remove the two outside frame pieces by

removing two screws per side. See diagram
below.

7) At this point you should disconnect the gas

at the valve. You can access it through the
front now that the control panel is off, or you
can access it through the rear pedestal cover
plate.

8) Carefully remove the logs and lava rock.

9) Remove

burner.

If your valve requires maintenance or replace-
ment, use the following instructions:

Note: Always close off the gas supply

before removing the valve.

1) Open front pedestal door. You may want

to put a soft cloth on the base of the unit
so that when the pedestal door is open it
doesn't scratch the paint.

Note: Use a magnetic type screwdriver if

possible.

10) Remove all 18 screws holding the burner

tray assembly in place.

11) Carefully lift the burner tray assembly out.

12) To replace the burner tray assembly, simply

reverse these instructions.

MAINTENANCE

5) Disconnect the DC spark generator wires

from the valve.

4) Remove the screw that holds the DC

spark generator wires in place on the
valve.

This manual is related to the following products: