beautypg.com

Connection procedure (see figure 3), External dimensions and a sample foot pattern, Connection procedure – Renesas R0E53036ACFK40 User Manual

Page 3

background image

(3/4)

5. Connection Procedure

(See Figure 3)


The procedure for connecting the R0E53036ACFK40 is shown
below.

(1) Mount the NQPACK064SD-ND on the user system.

(2) Attach the YQPACK064SD on the NQPACK064SD-ND.

(3) Secure the four corners of the YQPACK064SD with the

YQ-GUIDEs.

Do not use the screws included with the

YQPACK064SD for fixing the YQPACK064SD.

Do NOT use the screwdriver included with the

NQPACK064SD-ND for fixing the YQ-GUIDEs. That

is used only for the HQPACK064SD.

(4) Mount the R0E53036ACFK40 on the YQPACK064SD.

(5) Connect the flexible cable R0E001000FLX10 of the

emulator to the R0E53036ACFK40.

Figure 3 Connection procedure of the R0E53036ACFK40

6. External Dimensions and a Sample Foot Pattern

10

.0

0

14

.0

0

10.00

14.00

0.50

0.25

Unit: mm

16.5

0

CN1

1

50

51

100

24.00

38

.00

TP1

TP2

R0E53036ACFK40

REV.A

M

A

D

E

IN
J

A

P

A

N

Pb
F

ree

2.50

9.50

2.50

9.

50

Figure 4 External dimensions and a sample foot pattern of the R0E53036ACFK40