beautypg.com

Connection procedure, External dimensions and a sample foot pattern, Connection procedure (see figure 3) – Renesas R0E521258CFJ00 User Manual

Page 5

background image

(3/4)

5. Connection Procedure (See Figure 3)


The procedure for connecting the R0E521258CFJ00 is shown
below.

(1) Mount the NQPACK052SB on the user system.

(2) Attach the YQPACK052SB on the NQPACK052SB.

(3) Secure the four corners of the YQPACK052SB with the

YQ-GUIDE's.

Do not use the screws included with the

YQPACK052SB for fixing the YQPACK052SB.

The screwdriver included with the NQPACK052SB is

used for fixing the HQPACK052SB. Do not use it for

fixing the YQ-GUIDE's.

(4) Attach the R0E521000EPB00 or R0E521000CPE00 to the

R0E521258CFJ00.

(5) Attach the R0E521258CFJ00 to the YQPACK052SB.


























Figure 3 Connection procedure of the R0E521258CFJ00

52-pin 0.65-mm-pitch
(PLQP0052JA-A) foot pattern

YQ-GUIDE(x4)

YQPACK052SB

NQPACK052SB

(1)

(2)

(4)

(5)

R0E521258CFJ00

(3)

V

Be sure to use a
flathead screwdriver.

R0E521000EPB00

or

R0E521000CPE00


6. External Dimensions and a Sample Foot Pattern (See Figure 4)

Figure 4 External dimensions and a sample foot pattern of the R0E521258CFJ00

37.0

16.

5

32

.0

0.4

0.65

9.0

13.0

9.

0

13

.0

Unit: mm

CN1

15

0

R0E521258CFJ00 REV.A

MADE IN JAPAN

IC

1