Treme control, Simple serviceability, Temptracker mod – Raypak XTHERM 1505 User Manual

Page 7: On-board diagnostic center, Diagnostic information

background image

7

X

treme Control

Simple Serviceability

Raypak’s easy-to-understand user interface, including
on-board diagnostics and LED operating status lights,
tells the technician all he needs to know. All
service/repair components are readily accessible from
the front or side for maximum installation flexibility.
To enhance serviceability, the control box is completely
removable allowing total access.

TempTracker Mod

Raypak’s XTherm comes standard with TempTracker Mod. This control can be used for
space heating and hot water supply with 8 application-specific modes to meet various
applications, including outdoor reset for heating systems. The control monitors and dis-
plays inlet and outlet temperatures on all applications as well as monitor outdoor tem-
perature when an outdoor reset mode is selected. Only Raypak’s TempTracker Mod
allows for a user definable outdoor reset ratio. Adjustable limits prevent over-cycling,
saving energy and extending the life of the heater. Your XTherm is never down with a
sensor failure thanks to Raypak’s exclusive TempTracker software. It can operate with as
little as one functioning sensor, keeping you up and running until service arrives.

P or PID logic

0-10VDC Setpoint Input

0-10VDC Direct Drive Input

4-20ma output

Building management direct control

LCD Display

Freeze Protection

On-Board Diagnostic Center

Raypak’s XTherm comes equipped with a microprocessor-controlled diagnostic control center that displays its information on a
2x20 character LCD display in plain English. This control monitors system safeties, ignition faults and system status, while storing
up to 16 reported faults. Raypaks diagnostic center monitors the fault outputs of the Fenwal ignition control. Converting the
Fenwal’s flashing lights into real English fault codes that anyone can understand. The control is also equipped with a SPDT dry
contact relay output that is switched anytime a safety fault occurs. This can be used for a heater alarm or a BMS safety interface.

Example Diagnostic Fault Report

Diagnostic Information

Safety Faults

Ignition Control Faults

Condensate Drain

Low Air

Manual High Limit

Flame- No CFH

Auto High Limit

Ignition Lockout

Low Water Cut-off

Low HSI Current

Vent Pressure

Low 24VAC

High Gas Pressure

Internal Control Fault

Low Gas Pressure

Controller Alarm

Flow Switch

Blower Switch

Factory Option

External Interlock

Cold Water Run

Water Flow Sw Fault

Check Boiler Pump, Purge Air, Replace Flow Switch