Specifications

Continuous Power Output

35 watts/ch

(20-20 kHz, < 0.03%, 8 ohms)
Total Harmonic Distortion (20Hz-20kHz)

< 0.03% at rated power,
1/2 power or 1 watt

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

< 0.03% at rated power,
1/2 power or 1 watt

Frequency Response

Phono Input

20Hz-15kHz,

±

0.3dB

Line Level Inputs

10Hz-40kHz,

±

1dB

Damping Factor (20-20,000 Hz, 8 ohms)

180

Input Sensitivity / Impedance

Phono Input

2.5mV / 47 kOhms

Line Level Inputs

150 mV / 20 kOhms

Input Overload

Phono Input

180mV

Line Level Inputs

5V

Tone Controls - Bass /Treble

±

6 dB at 100Hz / 10kHz

Signal to Noise Ratio (IHF “A” weighted)

Phono Input

80 dB

Line Level Inputs

100 dB

Power Requirements

USA Version

115 Volts, 60 Hz

European Version

230 Volts, 50 Hz

Power Consumption

180 Watts

Dimensions (W x H x D)

440 x 92 x 347 mm
17

3/8

x 3

5/8

x 13

11/16

Weight (net)

5.5 kg, 12.1 lbs.

All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Troubleshooting

Most difficulties in audio systems are the result of incorrect con-
nections, or improper control settings. If you encounter problems,
isolate the area of the difficulty, check the control settings, deter-
mine the cause of the fault and make the necessary changes. If
you are unable to get sound from the RA-932 refer to the sugges-
tions for the following conditions:

Power Indicator Is Not Lit

The Power Indicator should be lit whenever the RA-932 is plugged
into the wall power outlet and the Power Switch is pushed in. If it
does not light, test the power outlet with another electrical de-
vice, such as a lamp. Be sure the power outlet being used is not
controlled by a switch that has been turned off.

Fuse Replacement

If another electrical device works when plugged into the power
outlet, but the Standby Indicator still will not light when the
RA-932 is plugged into the wall outlet, it indicates that the internal
power fuse may have blown. If you believe this has happened,
contact your authorized Rotel dealer to get the fuse replaced.

No Sound

Check the signal source to see if it is functioning properly. Make sure
the cables from the signal source to the RA-932 inputs are connected
properly. Be sure the Listening Selector is set to the proper input.
Check the wiring between the RA-932 and the speakers.