Selecting power fasteners and power loads – Remington r300 User Manual
Page 13
13
119586
FaStEnInG IntO COnCrEtE
The proper power fastener length
can be determined by adding the
thickness of the material to be
fastened and the amount of power
fastener that will actually penetrate
the concrete. The concrete must be
three times as thick as the intended
power fastener penetration. In most
cases, penetration should be ap-
proximately 1" to 1
1
/
4
" into the base
concrete material.
FaStEnInG IntO StEEL
The proper power fastener length can
be determined by adding the thick-
ness of the material to be fastened
and the thickness of the steel. The
point of the power fastener must go
completely through the steel.
pOWEr LOaDS
Always start with the lowest power
level (gray-level 1). If the first test
power fastener does not penetrate to
the desired depth, move to the next
highest power level (brown-level ).
Increase until a proper fastening is
made.
ImpOrtant: Damage to the
tool will result if the above instruc-
tions are not followed (see illustra-
tions to right and lower right).
OVErDrIVEn pOWEr
FaStEnErS anD pIStOn
An overdriven power fastener re-
sults when too strong of a power
load is used causing the piston to
extend past the muzzle. Move to the
next lightest power load. Repeated
overdrive will damage your tool. By
avoiding overdrive, you can extend
the life of your tool considerably.
nOtE: nEVEr fire the tool without
a power fastener. This can damage
the tool and/or cause possible injury
to the operator.
Selecting power
Fasteners and
power Loads
piston Extended
Out of muzzle
OVErDrIVE
Wood or non-metals
to Steel
Wood or non-metals
to Concrete
Flush With Surface
rIGHt