5. Connection Procedure (See Figure 3)


3. Mount the NQPACK048SD.
4. Attach the YQPACK048SD on the NQPACK048SD.
5. Secure the four corners of the YQPACK048SD with the

YQ-GUIDE's.


6. Attach the M34553T-PTCB to the YQPACK048SD.
7. Connect the M34553T-PTCA converter board to the

M34553T-PTCB.


Before using the M34553T-PTCB, be sure to read "7.
Precautions" on page 4.

Figure 3 Connection procedure of the M34553T-PTCB

6. External Dimensions and a Sample Foot Pattern (see Figure 4)

Figure 4 External dimensions and a sample foot pattern

z Do NOT use the screws included with the

YQPACK048SD for securing it.

z Do NOT use the driver included with the

NQPACK048SD for securing the YQ-GUIDE’s. It is
used for securing the HQPACK048SD.

M34553T-PTCA

M34553T-PTCB

YQPACK048SD

NQPACK048SD

(4)

(2)

(3)

(5)

(1)

YQ-GUIDE’s (x4)

48-pin 0.5-mm-pitch
(48P6Q-A) foot pattern

Use a flat blade driver.

Target system

These corners are not round.

: No. 1 pin position
Be sure to align the pin.

CN1

J1

1

25

26

50

MADE IN JAPAN

1

12

13

24

25

36

37

48

RENESAS

M34553T-PTCB REV.A

35

35

0.5

28

Unit: mm

0.5

0.25

10

6.5

10

6.

5