30

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

Mitred Glass Replacement

Removing Glass

1) Remove the door from the unit and place on

a soft surface to prevent scratching.

2) Pull out the door gasket.

3) Remove the 24 nuts holding the glass

retainers in place. Do not remove the nuts
underneath the retainers.

4) Remove the door catch plate.

5) Remove glass retainers on sides first (3

each side) then remove two center retain-
ers.

Note: Center glass retainers are glued

to center glass.

6) Remove glass from extrusions. When re-

moving center glass, leave white insula-
tion in place.

Installing Glass

2) Place glass assembly into door frame.

3) Install retainers by placing 1 drop of glue

where previously glued and put in place.

4) Install side retainers.

5) Install door catch plate.

6) Install the 24 nuts loosely, do not tighten yet.

1) Install both center

and side glass
onto extrusions as
per diagram.

Panel Glass Door Assembly

Wraparound Assembly Door

(same glass retainers as the

Panel Assembly)

Note:

Wearing gloves will protect your hands
while handling glass.

Panel Glass Replacement

1) Remove the door from the unit and place on

a soft surface to prevent scratching.

2) Pull out the door gasket.

3) Remove the nuts holding the glass retainers

in place.

4) Remove the glass retainers (sides, top and

bottom) and the door catch plate.

5) Replace the glass. The glass must have

gasketing around it.

6) Reverse the previous steps, replace the

retainers and fasten with the nuts but do not
overtighten, as this can break the glass.
Note: the door catch plate fits on top of the
left side retainer.

7) Put gasket glue on the retainers, but do not

put glue on the screws. Replace the door
gasket, the two ends butt tight together on
the bottom edge of the door.

8) Replace door on the stove and check the

seal.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.

Note: Improper positioning of logs may

create carbon build-up and will al-
ter the unit’s performance which
is not covered under warranty.

DOOR GASKET

If the door gasket requires replacement use 7/
8" diameter oval door gasket (Part # 650-920).

LATCH ADJUSTMENT

The door latch may require adjustment as the
door gasket material compresses after a few
fires and after glass replacement. Turn the
adjustable catch to tighten or loosen the latch.

GLASS

REPLACEMENT

Your ULTIMATE stove is supplied with high
temperature, 5 mm Neoceram ceramic glass
that will withstand the highest heat that your
unit will produce. In the event that you break
your glass by impact, purchase your replace-
ment door from an authorized Regency dealer
only, and follow our step-by-step instructions
for replacement. The glass is not sold sepa-
rately, as it must be properly sealed in the door
frame.

Replacement Part #

940-325/P

U39 Wraparound Glass

940-322/P

U39 Panel Center Glass

940-323/P

U39 Panel Side Glass

WARNING: Do not operate appli-
ance with glass panels removed,
cracked or broken. Replacement of
the glass should be done by a li-
censed or qualified service person.

MAINTENANCE