Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

NOTE: For Snorkel terminations in ABOVE
grade installations, follow national or lo-
cal code requirements.

Diagram 3a

Note: Riser
Vent is only for
use in above
grade termi-
nations.

U39: 59-3/4" (1518mm)

Diagram 2

Note:

a) The horizontal run of vent should have a 1/

4 inch rise for every 1 foot of run
towards the termination. Never allow
the vent to run downward. This could
cause high temperatures and may
present the possibility of a fire.

b) The location of the horizontal vent ter-

mination on an exterior wall must meet
all local and national building codes,
and must not be blocked or obstructed.
For External Vent Terminal Locations,
see diagram on page 8.

c) Snorkel Terminations:

For installations requiring a vertical rise
on the exterior of the building, 14-inch
and 36-inch tall Snorkel Terminations
as shown in Dia. 3 are available, as well
as the standard Riser Vent, see Dia. 3a.
Follow the same installation procedures
as used for standard Horizontal Termi-
nation. NEVER install the snorkel up-
side down.

*Dia 3, 3a & 4: As specified
in CGA B149 Installation
Code. Local codes or reg-
ulations may require dif-
ferent clearances.

b) Horizontal runs of vent must be sup-

ported every three feet. Wall straps
are available for this purpose.

3) With the pipe attached to the stove, slide

the stove into its correct location, and mark
the wall for a 10" x 10" (inside dimensions)
square hole. The center of the square hole
should line up with the centerline of the
horizontal pipe, as shown in diagram 2. Cut
and frame the 10 inch square hole in the
exterior wall where the vent will be termi-
nated. If the wall being penetrated is con-
structed of non-combustible material, i.e.
masonry block or concrete, a 7" diameter
hole is acceptable.

Diagram 3

INSTALLATION

DURA-VENT

HORIZONTAL

INSTALLATIONS

1) Set the unit in its desired location. Check to

determine if wall studs or roof rafters are
in the way when the venting system is
attached. If this is the case, you may want
to adjust the location of the unit.

2) Direct Vent pipe and fittings are designed

with special twist-lock connections to con-
nect the venting system to the appliance
flue outlet. A twist-lock appli-
ance adaptor is installed on the
unit at the factory. Assemble
the desired combina-
tion of pipe and elbows
to the appliance adap-
tor with pipe seams
oriented towards the
wall or ceiling, as much
out of view as possi-
ble. The final position-
ing of the pipe
and 90

o

elbow

assembly is de-
termined by the
mounting orien-
tation of the

Diagram 1

911B

11"-14 5/8" Adj. Pipe Length-Black

917B

17"- 24" Adj. Pipe Length Black

945

45

O

Elbow Galv.

945B

45

O

Elbow-Black

945G

45

O

Elbow-Swivel Galv.

945BG

45

O

Elbow-Swivel-Black

990

90

O

Elbow Galv.

990B

90

O

Elbow-Black

990G

90

O

Elbow-Swivel Galv.

990BG

90

O

Elbow-Swivel-Black

991

High Wind Term. Cap (Vertical)

980

Vertical Term. Cap

984

Horiz. Sq. Term. Cap

985

Horiz. Sq. High Wind Term. Cap

982

Snorkel-14" Rise Term.Cap

981

Snorkel-36" Rise Term.Cap

940

Wall Thimble-Support/Box

941

Cathedral/Ceiling-Support/Box

3951

Brass Trim-Wall Thimble/
Ceiling Support

963

Firestop Spacer

943

Flashing 0/12-6/12

943S

Flashing 7/12-12/12

953

Storm Collar

950

Vinyl Siding Standoff

988

Wall Strap

942

Wall Thimble

Parts not supplied by Dura-Vent
946-506/P Vent Guard (Optional)
640-530

Riser Vent Terminal (Optional)

948-128

Vinyl Siding Shield for Riser
Vent Terminal

946-228

Horizontal Square Termination Cap

adaptor on the stove and twist-locked for
a solid connection.

Note:
a) Twist-lock procedure: Four indenta-

tions,

located on the female ends

of pipes and fittings, are designed to
slide straight onto the male ends of
adjacent pipes and fittings, by orienting
the four pipe indentations so they match
and slide in to the four entry slots on the
male ends (diagram 1). Push the pipe
sections completely together, then
twist-lock one section clockwise ap-
proximately one-quarter turn, until the
two sections are fully locked. The fe-
male locking lugs will not be visible from
the outside on the Black Pipe or fittings.
They may be located by examining the
inside of the female ends. Apply sealant
"Mill-Pac" to inner pipe and high temp
silicone sealant to outer pipe on every
twist-lock joint.

Hint: Apply
silicone to female
end.