beautypg.com

Installation – Regency ULTIMATE U39-NG User Manual

Page 14

background image

14

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

INSTALLATION

Note: if the centerline cannot be
met, the adjustable sections will
have to be cut.

e) Cut the 2 ft. or 4 ft. section of rigid pipe

to length. Ensure that the pipe length
when cut will seat onto both the start-
er collar and the 90

o

elbow. Crimped

section of rigid pipe seats into
the 90

o

elbow. Only cut the un-

crimped side of pipe.

Dismantle all pipe sections including vent
terminal.

3) Attach the 4" dia. flex liner to the vent

terminal ensuring that the flex overlaps the
collar of the vent terminal by a minimum of
1-3/8"(35mm). Use Mill-Pac to seal and

secure with 3 of the #8 x 1/2" screws
(stainless steel).

4) Attach the adjustable pipe section to the

vent terminal using Mill-Pac and/or high
temperature silicone and attach with 3 of
the #8 x 1/2" screws (stainless steel).

Hint: Apply the sealant (Mill-Pac and/or high
temperature silicone) to the outer pipe be-
fore connecting the inner pipe.

brick, concrete, or other types of
sidings.

6) A bead of non-hardening mastic should be

run around both the termination and vinyl
siding standoff to prevent water from en-
tering and to make a tight seal between the
cap and the standoff.

7) Stretch the 4" dia. flex liner out fully and get

a trial fit of the liner onto the 4" dia. starter
collar.

8) Cut the 4" dia. flex liner to the desired size.

Hint: leave an extra 12" to 16" of length, this
will make the final assembly easier to work
with.

9) Secure the 4" dia. flex liner to the 4" adapter

with Mill-Pac and 3 of the #8 x 1/2" screws
(stainless steel).

10) Slide the decorative Thimble Cover over the

pipe sections and secure with 4 screws
(#8 x 1-1/2" drill point, black) to the wall.

11) Slide the 90

o

elbow (crimp end up) and the

2 ft. or 4 ft. pipe section (crimp end up) over
the 4" dia. flex liner.

12) Slide the trim collar over the adjustable pipe

sections to cover the joint of the telescopic
section.

13) Install the spring spacers onto the pipe

sections.

14) Secure the 4" dia. flex liner with adapter

onto the stove collar. Put a bead of Mill-Pac
around the appliance adapter and secure
with 3 screws (#8 x 1/2, stainless steel).

15) Attach the pipe section onto the starter

collar by sealing with Mill-Pac and/or high
temperature silicone and securing with 3 of
the #8 x 1/2" (black) screws. Pipe seams
should be facing the wall.

16) Attach the 90

o

elbow onto the pipe section

by sealing with Mill-Pac and/or high temper-
ature silicone and securing with 3 of the #8
x 1/2" screws (black).

17) Slide the adjustable pipe section onto the

90

o

elbow. The flex may have to be com-

pressed back in order for the adjustable
pipe to properly mate to the elbow. Seal
with Mill-Pac and/or high temperature sili-
cone and secure with 3 of the #8 x 1/2"
screws (black). Pipe seams facing down.

18) Install the trim collar over the starter collar

and secure with a #8 x 1/2" screw (black).

If the pipe needs to be touched up, use only
Stove Brite High Temperature Metallic Black
Stove Paint.

NOTE: All inner joints must be sealed

with Mill-Pac.

All outer joints may be sealed with
high temperature silicone.

more aesthetically pleasing, we
recommend fram-
ing out a square
that the cap can be
mounted on.

Note: If installing termi-

nation on a siding
covered wall, a vi-
nyl siding standoff or furring strips
must be used to ensure that the
termination is not recessed into
the siding. For vinyl siding stand-
off installation refer to the Dura-
Vent Termination instructions.

5) Slide the partially connected pipe and vent

terminal assembly through the wall thim-
bles (from the exterior into the interior) and
secure the cap to the exterior wall with 4
of the supplied screws (#8 x 1-1/2" drill
point, stainless steel). Note: pilot holes will
need to be drilled through the wall thimble
on all 4 corners.

Note: The four screws provided for the

vent cap should be replaced with
appropriate fasteners for stucco,

Note: The pipe

s e a m
should be
f a c i n g
down.

Note: To make

the instal-
l a t i o n

This manual is related to the following products: