beautypg.com

Hampton® gas products, Accessories, Gas stoves – Regency H15 User Manual

Page 14

background image

* The H15 can be vented horizontally with the AstroCap™ system. For rear vent applica-

tions, H25 requires a riser vent; H35 requires a riser vent and BTU reduction kit.

** H35 requires minimum 1ft. rise.

H15/H25/H35*

H15/H25/H35**

H15/H25/H35

D

D

A

A

B

A

A

C

Left Side W

all

Right Side W

all

Left Side W

all

Right Side W

all

Clearances To Combustibles

H15

H25

H35

A Side Wall To Unit

6"

6"

6-1/2"

B Back Wall To Unit

0"

3"

6"

C Vertical Vent to Back Wall

2"

2"

2"

D Side Wall To Unit (Corner)

2"

2"

2"

Minimum clearance of vent terminal to outside corner and inside corner: AstroCap™ 6", Dura-Vent Cap 12"

Dimensions

H15

H25

H35

A

20-11/16"

22-5/8"

27"

B

22-1/2"

27"

28"

C

14-1/4"

14-1/4"

19-3/4"

D

16-3/16"

16-7/16"

21"

Shipping Weight

182 lbs.

196 lbs.

308 lbs.

A

B

C

D

A

B

C

D

Hampton® Gas Products

Specifications

H15

H25

H35

NG

LP

NG

LP

NG

LP

Maximum BTU

18,000

18,000

25,000

23,000

36,000

34,000

Turn down to (BTU)

10,500

10,600

12,500

11,500

18,000

17,500

EnerGuide rating (Canada only)

62.31%

62.31%

61.15%

61.63%

68.34%

69.72%

Efficiency

80%

82%

83%

85%

83%

85%

Herringbone - Rustic Brown

Standard - Rustic Brown

Standard - Old Town Red

FireGenie® Remote Control

Turn your Hampton on and off from the comfort of your
sofa with the easy-to-use FireGenie.

Programmable Thermostat

Set a specific temperature with a Hampton wall thermo-
stat and maintain a constant comfort level in your home.

Brick Panels

Add one of three fully textured brick panels.
Note: Herringbone is not available for the H35.

gas stoves

accessories

NOTE: PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. BEFORE INSTALLING REFER TO THE RELEVANT PRODUCT MANUAL FOR FULL AND UP
TO DATE INFORMATION.
H15: Tested to the following standards:ANSIZ21.88-2003/CSA33-2002, CGA 2-17-M91
H25: Tested to the following standards: Gas-Fired Appliances For Use At High Altitudes CGA 2-17-M91, Vented Gas Fireplace Heaters ANS Z21.88a-2000/CSA 2.33a-2000.
Certified for Canada and the US.
H35: Tested to the following standards: CGA 2-17-M91, ANSIZ21.88b-1999/CSA 2.33b-M99. Certified for Canada and the US.
H15, H25 and H35 are approved for bedroom, alcove and mobile home installations.
All products tested to the following standards: GRAVITY DIRECT VENT WALL FURNACE TESTED AND APPROVED FOR U.S.A. AND CANADA TO: CAN/CGA-2.17-M91, ANSI
Z21.88b-1999/CSA 2.33b-M99.