Connection procedure, External dimensions and a sample foot pattern, Connection procedure (see figure 3) – Renesas M3T-FLX-120NSE User Manual
Page 5

(3/4)
5. Connection Procedure (See Figure 3)
The procedure for connecting the M3T-FLX-120NSE is shown
below.
(1) Mount the NQPACK120SE on the target system.
(2) Attach the YQPACK120SE on the NQPACK120SE.
(3) Secure the four corners of the YQPACK120SE with the
YQ-GUIDE's.
● Do not use the screws included with the
YQPACK120SE for fixing the YQPACK120SE.
● The screwdriver included with the NQPACK120SE is
used for fixing the HQPACK120SE. Do not use if for
fixing the YQ-GUIDE's.
(4) Connect the probe of the emulation pod to the
M3T-FLX-120NSE.
(5) Attach the M3T-FLX-120NSE on the YQPACK120SE.
Figure 3 Connection procedure of the M3T-FLX-120NSE
6. External Dimensions and a Sample Foot Pattern
Figure 4 External dimensions and a sample foot pattern of the M3T-FLX-120NSE
YQ-GUIDE (x4)
(1)
(2)
(3)
(5)
(4)
Be sure to use a
slotted screwdriver.
Probe of emulation pod
M3T-FLX-120NSE
YQPACK120SE
NQPACK120SE
120-pin 0.4-mm-pitch
(120P6R-A) foot pattern
: No. 1 pin
Be sure to align the pins.
55.0
21.8
40
.0
5.
3
0.225
0.4
13.0
17.0
13
.0
17
.0
Unit: mm