34-1/2

A

2"
WATER
CONNECTION

34-1/2

8

10-7/16

4-11/16

RHP 100

,

115, 160

Heat Pump

MODEL

100

115

160

Heat BTUH Output

102,000

112,000

158,000

80°F Air 80% RH 80°F Water

C.O.P.

5.4

6.4

6.4

Compressor

Scroll

Voltage

208/230V-1Ph-60Hz

Minimum Circuit Ampacity

37

40

46.2

Maximum Breaker Size (

Amps

)

50

50

60

Electrical Input (kw)

5.58

6.12

6.84

Water Flow (gpm)

15-80

15-80

28-80

Shipping Weight (lbs.)

300

325

405

Dimensions

Technical Specifications

2151 Eastman Avenue, Oxnard CA 93030 • (805) 278-5300 Fax (800) 872-9725

www.raypak.com

• Exclusive DuraSteel

TM

Cabinet

Polyester-coated, non-corrosive cabinet is more durable than
plastic heat pump cabinets.

• Copeland® Scroll Compressor

Largest high-efficiency, single-phase scroll compressor available
today.

• Large Marine-Grade Cupro-Nickel Heat Exchanger

Provides 25% more surface area and up to 15% more efficient
heat transfer than ordinary heat exchangers. Made from 722
marine-grade cupro-nickel.

• Large Coated Air Coils

Large fins maximize heating at lower temperatures. Unique fin
coating prevents corrosion, even in salt air.

• Venturi Fan Cowling

High-capacity fan provides unrestricted air flow for better
heating.

• Remote Compatible

Compatible with most major pool control and remote systems.

• Solid State Controls

Accurately monitors your pool’s water temperature settings.

• Plumbing Connections

2” PVC unions for ease of installation.

• Standard Dual Thermostats

Allows separate pool and spa temperature settings.

• Exclusive Direct-Set Thermostat

Just set the desired temperature and the thermostat does the rest
automatically.

• Internal Valving

Automatically compensates for normal day-to-day changes in
your pool’s hydraulics, maximizing heat transfer efficiency.

• Back-Flow Check Valves

Reduce the possibility of damage from chlorinating devices.

• Exclusive Refrigerant Receiver Tank

Allows larger refrigerant charge and more efficient heating at
lower air temperatures without additional compressor stress.

Features and Benefits

Model

A

100

32

115/160 37

Catalog Number: 6000.18D Effective 03-01-04 Replaces 02-01-04

Raypak reserves the right to change these specifications without notice.

All dimensions are in inches.