March 2008 Product Specifi cations Book

8

Gas Inbuilt

P

ellet Sto

v

es & Inser

ts

GFI55 Wood Pellet Insert

CLEARANCES TO COMBUSTIBLES

FIREPLACE SPECIFICATIONS

Your fi replace opening requires the following minimum sizes:

Height 55 lbs hopper (standard)
42 lbs hopper (adjusted)

22.75" (578mm)

19.5" (495mm)

Width

26" (660mm)

Depth

15" (381mm)

EXHAUST AND FRESH AIR INTAKE LOCATION

EXHAUST:

Base of unit to center of fl ue

9-1/16" (229mm)

Side of unit to center of fl ue

6-1/8" (156mm)

Center of unit to center of fl ue

5-3/4" (146mm)

FRESH AIR INTAKE:

Base of unit to center of intake

3-7/16" (87mm)

Side of unit to center of intake

10-7/8" (277mm)

Center of unit to center of intake

1" (25mm)

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENTING
MANUFACTURER.

1"

(25mm)

5

3

/

4

"

(146mm)

3

7

/

16

"

(87mm)

10

7

/

8

"

(277mm)

6

1

/

8

"

(156mm)

9

1

/

16

"

(229mm)

MASONRY FIREPLACE

INSERT INSTALLATION

Floor

Protection

Combustible Floor

Masonry Fireplace

Min. 6"

Rain Cap

Steel Plate or Flashing

Mantel (8" deep)

Fresh-air intake

Clean-out tee

If holes already exist

fresh-air intake can

be taken through the

back of the fireplace

or through the ash

dump.

Damper Removed
or Fastened Open

Min. 8" from

top of stove

OUTSIDE FRESH AIR CONNECTION

Outside fresh air is mandatory when installing this unit in airtight
homes and mobile homes.

A Fresh-air intake is strongly recommended for all installations.
Failure to install intake air may result in improper combustion as well as
the unit smoking during power failures.

When connecting to an outside fresh air source, do not use plastic or
combustible pipe. A 2” minimum (51 mm) ID (inside diameter) steel,
aluminum or copper pipe should be used. It is recommended, when you
are installing a fresh air system, to keep the number of bends in the pipe
to a minimum.

2" ID

(51 mm)

Optional

Elbow

Outside

Wall

The fi replace insert is certifi ed to be installed into a masonry fi replace only
and/or zero clearance wood burning factory built fi replace where allowed
by local codes. This model includes a surround faceplate and a pedestal.
When installing this unit, ensure that the pedestal is removed from the
inside of the hopper and installed on the bottom of the unit.

From the body of the heater to the:
Side

Wall

8"

(203mm)

minimum

Facing on Masonry Fireplace:

8" (203mm) minimum

8” (203mm) mantle:

8" (203mm) minimum