Rugged Outback RS416 User Manual
Page 20
20
2008 RuggedCom Inc. All rights reserved
Rev104
4.5 Console Port Wiring
A RS232 console port for configuration and management of the device is located on the LED
display module shown in Figure 13. This port is intended to be a temporary connection during initial
configuration or troubleshooting and allows for direct access to the serial-based management
console. The connection is made using the DB9-Female to RJ45 console cable included in the
device packaging shown below. Console connection settings are 57600 baud, no parity bits, 8 data
bits, and 1 stop bit.
Figure 13: Console port location on display board
Figure 14: Console cable
For user reference, the console cable pin-out is show in the table below.
RuggedCom RS232 over RJ45 pin-out specification
Signal Name (PC is DTE)
Female DB9
Male RJ45
DCD – Carrier detect
1
2
TxD – Transmit Data
2
5
RxD – Receive Data
3
6
DTR – Data terminal ready
4
3
Signal GND
5
4
DSR – Data set ready
6
1*
RTS – Ready to send
7
8
CTS – Clear to send
8
7
RI – Ring Indicator
9
1*
Table 4: RS232 over RJ45 console cable pin-out
After initial configuration, the RS416 can be configured via a number of mechanisms such as
Telnet, and the built-in web server. Consult the RuggedSwitch ROS User Guide for further details.
NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m
(6.5 ft) in length.