CONVERSION TO LOWER BTU RATING

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION!

Natural Gas Conversion Kit 730-920
Contains:
Qty. Part #

Description

1 904-240 Burner Orifi ce #37 (NG)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction

Sheet

Propane Conversion Kit 730-922
Contains:
Qty. Part #

Description

1 904-390 Burner Orifi ce #52 (Propane)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction

Sheet

1) Shut off the gas supply.

2) Open the front door. Carefully remove the

logs and lava rock.

3) Remove burner. See diagram below.

Burner Orifi ce

Note: Use a
magnetic type
screwdriver if possible.

Move Rear Log

Pins forward to

front holes.

Vent Restrictor setting at High 40,000 Btu/h

Vent Restrictor setting at Low 30,000 Btu/h

INSTALLATION

4) Unscrew the 2 Rear Log Pins and move to

the front hole position.

5) Remove Rear Log Bracket and slide the

Log Bracket Restrictor between the Rear
Log Bracket and the burner, secure with
the 2 screws.

7) Reinstall new burner orifi ce (NG stamped

#37 or LP stamped #52) and tighten.

8) Reverse steps 3) and 2).

9) Adjust Vent restrictor setting: To set the Vent

restriction as indicated in the diagram, simply
loosen the screws and push the vent restric-
tor plate to the correct position. Tighten the
screws.

Unit Btu/h

Restrictor

Opening

U38-1

40,000 A

1-3/8"

(35mm)

U38-1

30,000 B

1-1/8"

(29mm)

6) Remove burner orifi ce with a 1/2" wrench

and discard.

10) Attach the label "This unit has been con-

verted to..." on top of the Serial # decal over
the higher Btu information.

11) Check for gas leaks.

12) Check inlet and outlet pressures.

13) Check operation of fl ame control. Check

for proper fl ame appearance and glow on
logs.