Clearances

Unless otherwise stated the clearances listed below are Minimum

distances to combustible materials.

Please Note: A major cause

of chimney related fires is due to a failure to maintain required

clearances (air space) to combustible materials. It is of the greatest

importance that this fireplace and vent system be installed only in

accordance with these instructions.

Combustible Mantels

Because of the extreme heat this fireplace emits, the mantel

clearances are critical. Mantel may be installed anywhere in the

shaded area or higher.

Note: A non-combustible mantel may be installed at a lower

height.

Note: Ensure the paint that is used on the mantel and the facing

is “heat resistant” or the paint may discolour.

Clearances to Combustibles

Dimension

Description

E33S

A*

From Unit to Side Walls

8” (203mm)

B

From Unit to Ceiling

47” (1194mm)

C

Minimum Mantel Height

15” (381mm)

D

Maximum Mantel Depth

3-1/2” (89mm)

E

Alcove Width

76” (1930mm)

F

Alcove Depth

36” (914mm)

* Alcove side wall must have a minimum of 8” (203mm) clearance on one side.

Regency E33 Sunrise Gas Insert

E33S Sunrise Gas Insert